Loading...
522 w/MOD, Extension to previously approv, Studies & Reportsy . P Sheet 1 of 1 STATUS CHECKS (818) 458-4932 Tract/PM/Address Lot(s) 3 Parent Tract/PM Geologist Keith E h l e r t Geotechnical Engineer AGI • Los Angeles County Department of Public orks MATERIALS ENGINEERING DNISII GEOLOGIC REVIEW SHEET 900 S. Fremont Ave., Alhambra, CA 91803 T L. (818) 458-4923 T R 3 0 3 4 5 (-1') Location City of Rolling trills Developer Del Amo Savings Englneer/Arch, South B a y Review of: ROUGH GRADING AND FINAL GEOTECHNICAL REPORTS ✓Geologic Report(s) Dated (FINAL) 8 / 2 6 / 9 4 , 12 / 12 / 9 4 , 12 / 2 3 / 9 4 ✓Geotechnical Engineering Report(s) Dated (FINAL) 1 7/ 1 4/ 94 , 1 2/ 2 R/ 9 4 Geology and Geotechnical Engineering Report(s) Dated (FINAL) References:VGrading P.C. No. 4 3 4 8 Building P.C. No. For: Dist. Office 12.02 F NF DISTRIBUTION 2 Dist. Engineer _j Geologist Geotech. Engineer _I Geo/Soils File a Processing Center _ Health Dept. S FR On the basis of information in the above referenced report(s) rough grading is approved for Building Permits, from the standpoint of geology only, subject to those conditions checked below, for lot or address listed above. The above regort(s) contains recommendations that must be enforced, (Graded Subdivisions) Do not submit building plans to the Geology and Soils Section for structures on the pads created by the subject grading (no review required), provided code requirements and the consultant's recommendations are followed. All building plans for this lot(s), including the subject graded area, must be reviewed by the Geology and Soils Sections. The proposed building/structure site, as described in above referenced geology and/or sods reports, is geologically approved provided conditions contained in this review are followed. A private onsite sewage disposal system will be utilized. ; t4L/, L. k,,...J. f?.✓I;I;G.:, -�.i Special slope setbacks are required. Refer to the above referenced report dated setback requirements on building plans in detail and/or on plot plan. , for requirements. Show Foundation and/or wall/pool excavations must be respected and approved by the consulting ✓geologist, geotechnical engineer, prior to the placing of steel or concrete. The Geotechnical Engineering Units approval is attached (dated 1/17/95 ). Reviewed by Date 1 / 13 / 9 5 48-0052 9-6-94 F-RS:FORM.7 GITECHNICAL ENGINEERING REVI� SHEET COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS MATERIALS ENGINEERING DIVISION Address: 900 S. Fremont Ave. Alhambra, CA 91803 Telephone: (818) 458-4925 Buttress Tract 30345 Lot 3 Location #4 Canvon Mesa Lane, Rollina Hills Developer/Owner Del Amo Savinas Engineer --- Geotechnical Engineer AGI (4-1629-10) Geologist Ehlert (3171-94-AG) Final Grading Report (Grading Plan Check No. 4348 ) Review of: District Office Sheet 1 of 1 DISTRIBUTION: 12.02 I Drainage and Grading I Geo/Soils Central File _ District Engineer Geologist Geotechnical Engineer Engineer Geotechnical Addendum Dated 12/28/94 Geologic Addendum Dated 12/23/94 Geotechnical Addendum Dated 1/13/95 Refer to references in review sheet dated 12/20/94 ACTION: Plans are approved from a Geotechnical Engineering Standpoint. Prepared by r;e-e( Scott T. Ezell Date 1/17/95 NOTICE: Public safety, relative to geotechnical subsurface exploration, shall be provided in accordance with current codes for excavations, inclusive of the Los Angeles County Code, Chapter 11.48, and the State of California, Title 8, Construction Safety Orders. SR9.FGR4348