none, Correspondence - residential r, Studies & ReportsLIF,Li PALOS ILIVERDES UM Engineering 27520 Hawthorne Blvd. Suite 130 Rolling Hills Estates California 90274 pvec@earthlink.net 310 541 5055 Civil and Structural Consulting 310 541 0321 FAX Structural Calculations Foundation Underpinning & Rear Yard Improvements PREPARED FOR The Allocco Residence 20 Georgeff Road Rolling Hills, CA 90274 John O. Schuricht, S.E. SE 2391, exp. 3-31-97 Paul S. Christenson Project Engineer May 16, 1996 PVEC File No. 2-95-0581 LIA PALOS -ro- VERDES um Engineering Civil and Structural Consulting 27520 Hawthomo Blvd. Suito 130 Rolling Hills Estatos California 90274 310 541 5055 310 5410321 FAX Project Address: 20 GEo2GECP ROAD PVEC File No.- 2.- cis - 58 I PoLu . 1-11 LLs EST.., rA (1O2 74 Date: 4/Z 1 / 9 b 1.0 DATA: Code: 1994 Uniform Building Code. Timber: Douglas Fir No. 1 Horiz. Framing, unless noted. Glue Laminated Beams: Species Df, 24F-V4(DF/DF). Concrete: F'c=2000 psi @ 28 days per ACI 318. (FoorCz. SLABS) r'c : 3000 PSI. 2 28 DAH " " CGf1ADE BEAM Jo) Concrete Block: F'm=1350 psi, ASTM C-90, Grade N. Mortar: 1800 psi @ 28 days. Grout: 2000 psi @ 28 days. Reinf. Steel: ASTM A615-60 Grade, f5=24 ksi. Struct. Steel: A-36, Fy=36 ksi, fb=24 ksi: AISC 9th Ed. Welds: Low-Hyd. Rod - E70XX. Bolts: A307 Quality Minimum. Soils: Nb12CAl_ ENC.. WESTERN LArs. PaarEC,T: Soi2-94 PE/n- LT: q3 -161S Io/Z4 /94 12 J lri cr3 References: • PALOS VERDES ENGINEERING CORPORATION Consulling Structural Engineers 27520 1-IAWIII,ORNE BOULEVARD. SUITE 130 • ROLLING HILLS ESTATES. CA00274 TELEPHONE (310) 541-5055 • FAX (310) 541-0321 2,o LOAD5 2,1 ROOF LL1 OD c S -ffi E 1 K SI- EATih (O 2. R.2. 2 n C.J. I/2" G`-IP . 8D INSUL% MI SG 212 FLoorz 2.3 IJALLS EATE r2 oa. 15.0 PsF LSTIKLO' 2.4 PAsalEAT LffiLiS 2" ctac. 6L14 $4 PsF - JOU SIIECT NO 2-.95- s81 z CALCULATED DI CHECKED DY SCALE OF �p DATE 1129194 DATE 3.0 PsF 2.3 2,I 1.6 z.z DL= )2, o PsF LL = )L o PSF TL = 2f3 . o Ps F 2.0 PsF 2.3 3,S 1.z DL° 9, o PsF LL= 40,0 psE TL= 11,0 IV PALOS VERDES ENGINEERING CORPORATION Consulting Structural Engineers 27520 HAWT11011NE UOULEVAllO, SUITE 130 • nOLLING HILLS ESTATES. CA 90274 TELEPHONE (' 10) 541-5055 • FAx (310) 541.0321 3.0 GZADE BEAM DES1(�1\1 3.1 E ATEiZ1o2 - MAIN RCSIDe.k1CF. DLs JO„ 2-i2S S81 SHEET NO CALCULATED BY f 5L CHECKED DY SCA, r 1Zoor : 12.0 as r y G' = 72.0 P r LULL : 1S.D Psr, E'• 12o, o FL2; 9,o Psr• S= qS, o PTG r 4(p.ssuNE) 26s.o CAR. EN'2 `2r)4S = 380. 0 CIL = 1082. o Pic OF DATE SWUM DATE CJ= 2D 1 S Pit-- C.FAcroachi L ° SPMI Zo'-o'' CMAxi _ 2 Roo►-: 146.015r. 6 - 94 e‘r Mu= IIBv2o1KZ0 x 12 a ).Zile6 FLR t P6rts'= Zoo \114. x "2- 20i842o'" Z0 180 * LL = 2`1ra PIF -2 .2.12�1e U = -0. S9f O.S9� (aG,oa4 q CJ = 10224 2q6 - 1378 PIP r b = �cryb4 = -3000M 60.600M18K21" UT:�,1.1 log 2) C.1,7'c 296) - Z018 1''C G.801 a C = nkfcb- 1.211e.6.3aor,a18= 6.519e10 )ts- -b- -)b2-lac. 0.9K2a IGVc : (2 Fc J r 0, 2)5 4* (3000)"4 ISK21 = 3S� ►`(7 7 20,1604 & USE ST)2911P5 e 10110, c . 1.10m2 USE 3-tt 6 (Asa 1.121n7) USE )8" w21" &2ADE 11n -1 to/ 3 - IT 6 Tops Barr. 41 STIlziauPs ell"0.c. Palos Verdes Engineering Corp. 27520 Hawthorne Blvd, Ste 130 Rolling Hills Estates, CA 90274 (310) 541-5055 FAX (310) 541-0321 Title : AL.Locco Scope : Number: 2-gS-5&( Misc . Dsngr : Date:09-May-96 CONCRETE RECTANGULAR & TEE BEAM DESIGN Page `I DESCRIPTION » » Exter BEAM DATA SPAN = BEAM DEPTH BEAM WIDTH = 'T' FLANGE THICK. = FLANGE BOTH SIDES ? WEB SPACING INCLUDE BM. WT. STIRRUP AREA Eff. Slab Width --- REINFORCING ? n Allocco Residence Gr. Bm - Main Residence DESIGN DATA f'c = = Fy = SEISMIC ZONE (0=wind) = COMBINE LL & ST ? CONCRETE WEIGHT = Graphics: (1,2,3,4) : END CONDITIONS 20 ft 24 in 18 in in N y/n ft y/n 0.4 in^2 18 in LAYER #1... COUNT: SIZE: 'd' . LAYER #2... COUNT: SIZE: 'd' . CENTER Fix = 2 ... LEFT » Pin = 1 ... RIGHT » Free= 0 BOTTOM TOP 3 3 6 6 20 4 TRAPEZOIDAL: LEFT TOP BOTTOM 3 3 6 .6 4 20 APPLIED LOADS 3,000 psi 60,000 psi N y/n 145 pcf 3 RIGHT 1 « 1 « TOP BOTTOM 3 3 6 6 4 20 in in Dead Live Short #1: Load @Left = @ Right= #2: Load @ Left = @ Right= DISTRIBUTED: #1 = 1.082 #2 = #3 = POINT: #1 = #2 = #3 = #4 = #5 = MOMENTS: #1 = #2 = SUMMARY Mn*Phi : Center Mn*Phi : Left Mn*Phi : Right Vn*Phi: Left Vn*Phi: Right DL+[Bm Wt] DL+LL+[Bm Wt] 0.296 Location Start End klf ft klf klf ft klf klf ft klf ft klf ft k ft k ft k ft k ft k ft ft-k ft ft-k ft = 119 Mu : Center= = 119 Mu : Left = = 119 Mu : Right = 33.5 Vu : Left = 74.3 Vu : Right = ..Reactions(k) Left Right 10.82 10.82 13.78 13.78 9-1 9-2 --- 9-3 101 57 49 16.1 9.1 17.0 9.5 ft-k ft-k ft-k 7.8 k 8.2 k Deflections (in) Up @ X-Dist Down @ X-Dist 0.00 20.00 -0.06 10.00 ft 0.00 20.00 -0.11 10.00 ft Palos Verdes Engineering Corp. 27520 Hawthorne Blvd, Ste 130 Rolling Hills Estates, CA 90274 (310) 541-5055 FAX (310) 541-0321 Title : Au -Duo Scope : Number: 2-et��81 Misc : Dsngr : Date:09-May-96 CONCRETE RECTANGULAR & TEE BEAM DESIGN Page 5 DL+LL+ST+[Bm Wt]= 10.82 Stirrup Requirements: Dist. -> 2.5 5.0 Spacing ->999.00 999.00 Vu -> 16.14 15.34 10.82 0.00 20.00 7.5 999.00 9.69 10.0 12.5 999.00 999.00 5.38 9.96 -0.06 10.00 ft 15.0 999.00 15.34 17.5 ft 10.00 in 16.95 k ADDITIONAL DEFLECTION DATA Optional Location = ft ....(enter 0.0 for maximums) Neutral Axis = 4.52 in I : Gross = 20,736 in^4 I : Cracked = 3496 in^4 E : Elastic Mod. =3.1E+06 psi Fr : 7.5*(fc)A.5 = 410.8 psi Z:Cracking = 164.8 ksi Using Service Loads Only Mcr: Cracking = 59.2 ft-k Ms:Max DL+LL = 68.9 ft-k R1 = (Ms:DL+LL)/Mcr = 0.859 Ms:Max DL+LL+ST = 54.1 ft-k R2 = (Ms:DL+LL+ST)/Mcr= 1.093 I:eff... Ms(DL+LL) = 14,406 in^4 I:eff... Ms(DL+LL+ST) = 20,736 in^4 STATIC SECTION ANALYSIS For Evaluation of 'Mn' Moment Capacity: Center Left Right X : Neutral Axis = 3.00 3.00 3.00 a = beta * x = 2.55 2.55 2.55 Compression in Concrete = 117.23 117.236 117.236 Sum [Steel comp. forces] = Tension in Reinforcing = To Determine Mn, Use... Sections w/Tension Steel Only ----» Mn = T * (d-a/2) With Tension & Compression --» Mn = Cc * (d-a/2) + Sum(Cs*(d-d') For Evaluation of Max. As For X-Balanced Xmax = x * max % a -max = beta*Xmax Compression in Concrete Sum [Steel comp. forces] Total Compressive Force As Max.= Tot Force / fy Ductile in in kips kips -117.2 -117.23 -117.23 kips Failure: 11.84 8.88 10.06 346.4 59.7 406.1 6.77 11.84 8.88 10.06 346.4 59.7 406.1 6.77 11.84 8.88 10.06 346.4 59.7 406.1 6.77 in in in kips kips kips in^2 CAI -C2.all LAYOUT m romm nox =max PI 92 FOUNDATION PLAN P4 pS PALOS VERDES ENGINEERING CORPORATION Consulting Structural Engineers 27520 1 1AWT11011NE UDULEVAIID. SUITE 130 • ROILING HILLS ESTATES, CA90274 TELEPHONE (310) 541-5055 • FAx (310) 541-0321 4 ,o pi LE D E51c,r1 9, i VI eritA L PILE LOAD J0u SIIEET NO 7 OF CALCULATED DY T 5<'" CHECKED DY SCAT c DATE 57 I ci/t DATE T- 500 P5F ( 1'loaCAL 1 NG.) 2nr. coo = 2-rr<I.25'-r5coPsr _ 'fig 27 P P) 0/2 g 1378 Pfl' r 171 Pz z- (4-.-137S 17') _ 137fb X 171 = Pq ("2x 1378r 11')4CI)9.4 1378r IT35')4W78'(3,t l) PS 2 - 0/2, 137gc 15.76-') P6 02/x I3784 I5,70'L 1'9,,1378Y I g') P. zk C )►.•' 1378, 15') t. P$ ("/). • 137b" Ig')-(112.)37(x 12') Ii CPI .< )379 ' 121i L 1',.. 1379(11,S' ) PIO C i)2 137h, 14,CI,L1/7- 17$. 133') pig C51) 1.2 LATEQAL Au KEDOIMK L—F► r "5_o„ Ik713" = 231926't 23,42e • 27)3R = 21)76,9 • 23,ZSq I 211)901n • 20 T67ol • I$,2cii'' • 19,212z V= loop P[.r- 7,5' = 7Soo M = 75 oo4 [ 1. L7.5'/2 )] ; 12 = 727►500 n. lb As - 787,So0 _ 1.�31n2 Tsjd o,29.21%orowZ2.b ASLMIMo = 20o 6o, 000 x 26.6., Z2.4 _ LOG,A FMB 3=0" 6"- G_0" s'-9" 6 - D„ 6 _ III 5' 6" -'-G„ ZG USE g-a6 PALOS VERDES ENGINEERING CORPORATION54 Consulting Structural Engineers SIIEET Nr of 27520IIAwnwnNEUouLEVAnO.SUITE130 • fOLUNCHILLS ESTATES.CA90274 CALCULATED OY PS DATE 57I5")/6 TELEPHONE (310) 541-5055 • fax MO) 541-0321 CHECKED DY DAT6 . SCAL! V4 =24 JFC, bJ 0.8 S" - C3o0o112' 26. 6. 2Z .6 V. = SS.9'7» .Vu. > usE •tt 4 rlus ('12''a.c. UsE 3 o" 0 PILE IL)/ 8 # 8 VEiZT, `i TIES a' 12 "a.c, EMf3. ' 4 D FOR. LATEII2AI. = }D'- 2 USE r'i . I G - FMB ;r sEE ENE>?CA LL - ~ �- AmAL'rsIS . Ft.. 9 Palos Verdes Engineering Corp. 27520 Hawthorne Blvd, Ste 130 Rolling Hills Estates, CA 90274 (310) 541-5055 FAX (310) 541-0321 Title : ALiocCo Scope : Number: 2-9s-S% Misc : Dsngr : Date:15-May-96 DESIGN OF EMBEDDED POLE FOOTINGS Page i DESCRIPTION » Allocco Residence » Pile Embedment ALLOW PASSIVE psf 400 MAX PASSIVE psf 4,000 LOAD DURATION FACTOR 1 POINT LOAD LOAD Ht. DIST. LOAD START HT. END HT. WIDTH/DIAMETER CIRCULAR ? RESTRAINED ? SUMMARY lbs ft #/ft ft ft 7,500 in y/n y y/n N 8.75 30 N N N N Moments @ Surface: Point Load ft-# 65,625 Uniform Load ft-# ... Total Moment ft-# 65,625 Total Lateral Load # 7,500 --- NON -RESTRAINED RESULTS Min. Req'd Embedment A(1+(1+4.36h /A)^.5)/2 A=2.34P/(S 1 b) ft 10.12 zme, CONT.OLS Press @ 1/3 Embed.: Actual psf 1,348 Allowable psf 1,349 RESTRAINED Min. Req'd Embedment (4.25 P h/S3 b)^.5 ft Pressure @ Bottom Actual Allowable Surface Restraint Force psf psf lbs PALOS VERDES ENGINEERING CORPORATION Consulting Structural Engineers 275201'1AW111011NE (JOULEVAIID,SUITE 130 • (TOLLING HILLS ESTATES, CA 00274 TELEPHONE (310) 541-5055 • FAx (310) 541-0321 5,0 POoL DEsICG1J 5.1 POOL [?.TALL 6C PeF .loll ( SHEET NI I 0 of CALCULATED DY Ps DATC S! 1c7/6 CHECKED DY DATE SCALr EF P= G2.1 PcF IF ruLL .FP= Gs -Par 1r‘rO-W't Sou_ z 30Pa' Lv'ro GUa5F L60Tn 0 Psr . 0 oo 'sr — 2' op 4 II. C601- C G On. 5.311), C208o uM 2.67") ` GZ71 fI.lb = 75,283 •'1 A - 11 _ 75,2,g3 ► n jsj a 24,000A Al (.2) dSC' 12110,t 112 J 0,59, 1hz -V USE tf 6-& 6''o,c, Vr. 2i, (AA= 0,61 bSE 8a".(vALL cu ! .f S 6"o,c, VECT, Se " 21z I� o.c. 1-1 u ►b • Page 8 Project Number 5012-94 Foundation Desian A deep foundation system shall be utilized for the support of the proposed retaining wall. These foundations shall be designed with a safe bearing capacity of 2,500 psf for a minimum embedment of 24 inches into competent bedrock material with a minimum width of 12 inches. Alternatively, deep foundations resisting axial loads may utilize an allowable skin friction value of 500 psf along the embedded portion into firm bedrock. This value may be increased one third in consideration of short term loading from wind and seismic forces. Lateral resistance in firm bedrock may be obtained using an equivalent fluid pressure value of 400 psf per foot of depth below the bedrock contact. The bottom of the excavations should be kept reasonably free of loose or sloughed material. Caissons should be alternately poured with a minimum 10 hours spacing between adjacent caissons. Drilled piers shall be inspected and poured immediately after drilling. Pier excavation shall not remain open overnight. The drilling of the caissons should be performed under the supervision of a representative of this firm. The following values may be utilized in resisting lateral loads imposed on the wall structure. Requirements of the current Uniform Building Code should be adhered to when the coefficient of friction and passive pressures are combined: Coefficient of Friction - 0.35 Equivalent Passive Fluid Pressure = 200 lbs./cu.ft. Maximum Passive Pressure = 2,000 lbs./sq.ft. The passive pressure recommendations are valid only for either competent native soils and/or compacted fill soils. Settlement Analysis Resultant pressure curves for the consolidation tests are shown on Plate B. Computations utilizing these curves and the recommended safe bearing capacities reveal that the foundations will experience settlements on the order of 1/2 inch and differential settlements of less than 1/4 inch. NorCal Engineering