Loading...
429, Addition to SFR of more than 2, Correspondence• Ci1y e/ie0ti4 • INCORPORATED JANUARY 24. 1957 NO. 2 PORTUGUESE BEND ROAD ROLLING HILLS, CALIF. 90274 (213) 377-1521 FAX: (213) 377-7288 September 13, 1990 Dr. Michael Weller 3 Flying Mane Road Rolling Hills, CA 90274 Re: Zoning Case No. 429 - Request for Site Plan Review of residential additions Lot 49-SF Dear Dr. Weller: This is to inform you that the City Council, at their meeting on September 10, 1990, voted to ratify the Planning Commission's approval of the above referenced planning/zoning case application. Pursuant to Section 17.32.087, Ordinance No. 207, an Affidavit of Acceptance form must be executed before the approval becomes effective. A copy of the Resolution of Approval, specifying conditions of approval set forth by the Planning Commission, is enclosed for your information. Once you have reviewed the Resolution of Approval, please complete the enclosed Affidavit of Acceptance form, have the signature(s) notarized, and forward the Affidavit to the Office of the County Recorder, Room 15, 227 North Broadway, Los Angeles, CA 90012, with a check in the amount of $7.00. When the Affidavit of Acceptance has been returned to the City, duly executed and recorded, the Los Angeles County Department of Building and Safety will be notified that a permit can be issued. Please feel free to call me if you have any questions. Very truly, Ray (Ramada Principal Planner Encl. /jc • City 0/ leoffinv _AA September 9, 1991 Dr. Michael Weller 3 Flying Mane Road Rolling Hills, CA 90274 INCORPORATED JANUARY 24, 1957 NO. 2 PORTUGUESE BEND ROAD ROLLING HILLS, CALIF. 90274 (213) 377-1521 FAX: (213) 377-7288 SUBJECT: ZONING CASE NO. 429, 3 Flying Mane Road (Lot 49-SF) Request for a one year time extension Dear Dr. Weller: This letter shall serve as official notification that a one year time extension was APPROVED by the Plannning Commission at their adjourned regular meeting on September 5, 1991. We have enclosed a copy of RESOLUTION NO. 91-24, specifying that the Site Plan approval shall expire within two years of the approval of the original resolution, which will be August 4, 1992. Please feel free to call me at (213) 377-1521 if you have any questions. SINCERELY, LOLA UNGAR PRINCIPAL PLANNER cc: Mr. George Shaw, Edward Carson Beall Associates COASTLINE GEOTECHNICAL CONSULTANTS, INC. CONSULTING GEOTECHNICAL ENGINEERS 1446 W. 178TH STREET GARDENA, CALIFORNIA 90248-3202 Project No. 315C-091 Dr. and Mrs. Michael Weller No. 3 Flying Mane Road Rolling Hills, CA 90274 IECEIIWE 11 OCT - I gaol PROCESSING CENTER LAND DEVELOPMENT DIVISION Tel. (310) 217-1504 Fax (310) 217-1909 September 4, 2001 Subject: Reply No. 2 to Geologic and Soils Engineering Review Sheets from the County of Los Angeles Distressed Residence No. 3 Flying Mane Road Rolling Hills, California Dear Dr. and Mrs. Weller: This is written in response to a Geologic Review Sheet, dated July 11, 2001, and a Soils Engineering Review Sheet, dated July 13, 2001, concerning the subject project, prepared by the County of Los Angeles, Department of Public Works, Land Development Division. Copies of the review sheets are attached. RESPONSE TO BOTH GEOTECHNICAL REVIEWS The reviewers of the geotechnical reports, listed in the "REFERENCES" section of this response letter, seem to have missed the purpose of the proposed construction. The residence has settled due to a difference of supporting foundation materials. The majority of the residence is supported on footings on a graded cut, exposing bedrock on the east and south sides of the building. The west and some of the north sides. (excluding an addition) have footings founded on fill over natural clayey soil. The house settled in the direction of the deepest fill or depth to bedrock. The repair plan is very "common sense" - extend the foundations to the similar, non -settling material, and design for the lateral creep loads, if necessary. The proposed project information has been well documented, and a relatively simple fix. This repair, in the writer's opinion, could only improve the site conditions, and can see no reason for the County objecting to the repairs. Project No. 315C-091 2 Weller/Rolling Hills A review of the County's documents was performed. The findings of the research disclose the following information: Geotechnical reports of the site vicinity on file with the County of Los Angeles were reviewed by George DeVries, August 16, 2001. Data was available for #1, #5, #7, #9, and #10 Flying Mane Road and for #5, #7, and #10 Southfield Drive. Geological investigations for a proposed addition at #1 Flying Mane (north of and adjacent to the referenced site) were performed by Keith Ehlert (report dated 6/23/94) with soils engineering by SWN (report dated 6/26/94). One 60 foot boring and three test pits (9 to 15 feet) were excavated for that investigation. Bedrock was reported to underlie 2 to 7 feet of fill and soil. Bedrock consisted of bedded siltstone of the Monterey Formation. Bentonite was reported in Boring K-1 at 12.5 to 14.5 feet below ground surface (bgs) and Test Pit #3 from 9.5 to 14 feet bgs. Boring K-1 also encountered bentonitic siltstone at 41 to 45 feet bgs. Bedding attitudes showed some variability with location and depth. Cross sections (A -A' and B-B') show the west -facing slope below Flying Mane and above Southfield to be essentially a dip -slope with bedding approximately parallel to the slope. Investigations for a proposed riding rink at #5 Flying Mane were performed by Lockwood - Singh (report dated 3/5/74). Seven test pits were excavated with some bentonite reported in Test Pit #1, Test Pit #4, and Test Pit #6. The rink was proposed for the western portion of the property above Southfield Drive. Bedding attitudes were generally to the southwest and west. Additional investigations were performed by Keith Ehlert at #7, #9, and #10 Flying Mane. Bentonite was not reported from these sites. Distress to existing residences along Flying Mane has been reported predominantly along the west side of the street. The residences are constructed on pads with cut on the east side and fill on the west. Distress has been attributed to differential settlement of the foundation materials (cut -fill). This is consistent with the findings of our investigations at the referenced site. Geotechnical studies were performed for #5, #7, and #10 Southfield Drive by various investigators (#5 - Associated Soils, 10/19/83 and Geofon, 4/91; #7 - Maurseth-Howe- Lockwood, 7/21/66; #10 - AGI, 2/26/93 and 7/22/94). The presence of bentonite was not generally reported at these sites. A significant thickness of colluvial deposits is reported overlying bedrock in these areas. In summary, after a detailed review of the referenced geology for the site and vicinity, the conclusions and recommendations as presented in the- earlier geotechnical reports for the site are considered valid. While bentonite is reported throughout the site vicinity, landsliding is not reported in the immediate vicinity, nor is the site located within a zone Project No. 315C-091 3 Weller/Rolling Hills requiring evaluation for earthquake -induced landsliding (CDMG; 1997, SP 117). As noted in our 5/ 1/ 01 response, the nearest mapped landslides are located approximately 0.2 mile to the southwest (unnamed) and the west (Flying Triangle). Slope Stability The repairs to the property are not a slope stability issue. Bentonite beds exist, although random and discontinuous. However, to avoid future geotechnical reviews on the subject, additional slope stability calculations were performed, using the "benonite" strengths from the SWN report of June 26, 1994. Using the cross-section presented in the May 1, 2001 Reply letter, the location of which is shown on Plate 1A, and section shown on Plate 2A, new calculations were performed. The results of these calculations, shown on Plates 3A-R through 6A-R, indicates the factors of safety exceed the normally accepted minimums for stable slopes, for both static and pseudostatic analyses. 111 Statement - Based on the findings summarized in this letter and our prior reports, and provided the recommendations of these reports are followed, and the designs, grading, and construction are properly and adequately executed, it is our finding that construction within the building site will not be subject to geotechnical hazards from landslides, slippage, or excessive settlement. Further, it is our finding that the proposed underpinning will not adversely effect the stability of the site, or adjacent properties, with the same provisos listed above. Should there be any questions concerning this reply, please call. Respectfully submitted, COASTLINE GEOTECHNICAL CONSTS, INC. Richard A. Martin, RGE 563 George DeVries, CEG 1141 RAM/ GD/jm (5) Addressee (1) Palos Verdes Engineering REFERENCES The following geotechnical documents have been prepared for the site located at No. 3 Flying Mane Road, in Rolling Hills, California: 1. Coastline Geotechnical Consultants, Inc., April 20, 1990, "Geotechnical Engineering Investigation, Proposed Residential Additions", Project No. 315C-020. 2. George DeVries, May 4, 1990, "Preliminary Engineering Geology Investigation, Proposed Residential Addition", Project No. 1183-030. 3. Coastline Geotechnical Consultants, Inc., November 19, 1990, "Supplement to Report, Geotechnical Engineering Investigation, Proposed Residential Additions", Project No. 315C-020. 4. Coastline Geotechnical Consultants, Inc. and George DeVries, May 8, 2000, "Geotechnical Engineering. Investigation Report, Distressed Residence", Project No. 315C-030. 5. Coastline Geotechnical Consultants, Inc. and George DeVries, May 1, 2001, "Reply to Geologic and Soils Engineering Review Sheets", Project No. 315C-041. Sheet 1 of 1 REVIEWER CALLING HOURS 8-9 a.m. & 3-4 p.m. Mon.-Thurs. County of Los Angeles Department of Public Works LAND DEVELOPMENT. DIVISION GEOLOGIC REVIEW SHEET 900 S. Fremont Ave., Alhambra, CA 91803 TEL. (626) 458-4925 Tract/PM Parent Tract Site Address #3 Flying Mane Geologist (Coastline) George DeVires Soils Engineer Coastline Lot(s) Location Rollins Hills Developer/Owner Weller Engineer/Arch. Palos Verdes Engineering Review of: Building P.C. No. 0101120003 For: SFR Repair/Underpinning Geology and Soils Engineering Report(s) Dated 5/1/01 Action: Plan is not recommended for approval for reasons below. Remarks/Conditions: Dist. Office 12.02 F X NF DISTRIBUTION 1 Dist. Office 1 Geologist s Engr. 1 Section File _ Grading Sect. 1 Proc. Ctr. 1. The submitted statement in accordance with Section 111 of the Los Angeles County Building Code is inconclusive with regards to future settlement. 2. The Altamira Member of the Monterey Formation is known to contain lenses of very bentonitic tuff. Submit data which eliminates the possibility of these very weak material beneath the site and descending slope. The submitted data only describes.5 feet of the formation. If these very weak units exist beneath the site and descending slope utilize the appropriate strength in the slope stability analyses. 3. This office has files for 1,5,7,9 and 10 Flying Mane and several files for the properties along Southfield Drive. Please review these files and incorporate the information into the findings, conclusions and recommendations. 4. The Soils Engineering review dated 7/13/01 is attached. Date 7/11/01 NOTICE: Public safety, re tive to geotechnlcal subsurface exploration, shall be pro ded in accordance with current codes for excavations, Inclusive of the Los Ang r. s County Code, Chapter 11.48, and the State of Callf7 a, Title 8, Construction Safety Orders. The "Manual for Preparation of Geotechnical Reports" prepared by County of Los ngeles, Department of Public Works is available on the Internet at the following address: http://dpw.co.la.ca.us/med/manual.pdf p:\Idpubnew\geology revlew\forms\Form 6 5/15/01 Address: Telephone: Fax: Calling hours COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS LAND DEVELOPMENT DIVISION SOILS ENGINEERING REVIEW SHEET 900 S. Fremont Ave. Alhambra, CA 91803 (626) 458-4925 (626) 458-4913 - Monday through Thursday 8-9 a.m. & 3-4 p.m. Underpinning Location 3 Fivina Mane Road. Rollina Hills Developer/Owner Weller Engineer/Architect Palos Verdes Enaineerina Soils Engineer Coastline 9315C-030). Geologist DeVries Building Plan Check No. 0101120003 Review of: Building Plan Dated By Processing Center 6/20/01 Soils Addendum Dated 5/1/01 Geologic Addendum Dated Previous review sheet dated 2/5/01 ACTION: Plan is not recommended for approval. REMARKS: 5/1/01 District Office 12.02 Sheet 1 of 1 DISTRIBUTION: _ Drainage Grading 1 Geo/Soils Central File 1 District Engineer 1 Geologist 1 Soils Engineer 1 Engineer/Architect 1. The foundation design recommendations provided address only shallow footings. As previously requested, provide recommendations which specifically address the proposed deep foundation underpinning (e.g. axial and lateral capacity, downdrag, lateral loads due to slope instability and/or creep, ect.). Verify that the proposed deep foundation design, as shown on the building plans, is in accordance with the recommendations provided by the geotechnical engineer. 2. Requirements of the Geology Section are attached. 3. Include a copy of this review sheet with your response. Prepared by tea \� NOTICE: Public safety, relative to geotechnical subs eiOja , shall be provided in accordance with current codes for excavations, inclusive of the Los Angeles County Code, Ch , and the State of California, Title 8, Construction SafetyOrders. Mark:3aa Date 7/13/01 - ,/- ,-/ .,,, / / ..)."../ .,..,/ / ' 27 'V Z.'S...J.' ,z/ / /e" /./." ,/ :/// /./ f I WI vi. i.i. , 11,... .,". ft i • , ; t .vy .1...4 / i. ,,,„„ , : - ' i , A 1.- ' 4 Ii j: , -:'..---f i "---.— / ii sli jt '' f • A A 11 X 17 PRINTED ON NO. 1000H CLEARPHINT • • 1..." ,/ • \. 1 ,/l'ss,•1" / 1 / / / 7-Y I • ! SCALE: DATE: 18 I ct •.:. • i •iri ‘ / a s; / , // // / / ; / • / tiesticas; , \• \\-, \---/ i 1 A RI-110 P LA 0 i \ . \ ,. ....._. i • I s , \SY SO UTHIB tp*IE IN •••;..;., ".•-:•,_ 1,. ; \ *......_./ i - i i 1 •••1 ". .,...-...•. \ . .-1 j i . \ E• i : • : \ ! , • i ... • • • 1 i VICINITY MAP #3 FLYING MANE ROAD ROLLING HILLS ,CALIFORNIA APR 90 1"= I 001 APPROVED BY: •• 4 DRAWN BY REVISED JG COASTLINE GEOTECHNICAL CONSULTANTS PROJECT NO. 315C-091 DRAWING NUMBER GEOLOGIC CROSS .SECTION co Z i 3NVW JNIAid ' (1333) NOI±VA313 SECTION A -A' o 0 c O o 0 0 0 0 0 ammo • • _ N Slope Stability Analysis No. 7 Flying Mane Road Rolling Hills, California 0 00 ri ri MU U= V) ri Prot. II 315C-091 Plate 2A DeVr; i s►s—Ciorzs,u 1 t i,ri.g GoQ SLOPE STABILITY CALCULATIONS Parallel Cross Shear Strength Bedding Bedding Cohesion, psf 220 400 Friction Angle, 0 18 34 Itan cb 0.325 0.675 Section: A - A', Plane I (Unit Weight, pcf 120 120 Area Weight of Slide Driving Normal Length Segment Segment Plane sin a cos a Force Force (Ft2) (Kips/LF) Angle W Sin a W Cos a (Feet) 1 1112 133.4 7 - 0.122 0.993 16.3 132.4 112 2 163 19.6 55 0,819 0.574 16.0 11.2 26 F.S. = 32.3 143.7 E CL + E W cos a tan 0 ECL+(EWcosa—KEWsina)tan 0 F.S. _ EWsina EWsina+KEWcosa 35.0 + 50.6 35.0 + 48.2 ( K = 0.15) 32.3 53.8 85.6 83.2 = 2.65 = = 1.55 32.3 53.8 Geotechnical Engineering Investigation No. 3 Flying Mane Road Rolling Hills, California Project No. 315C-091 Plate 3A - R COASTLINE GEOTECHNICAL CONSULTANTS SLOPE STABILITY CALCULATIONS Parallel Cross Shear Strength Bedding Bedding Cohesion, psf 220 400 'Friction Angle, 0 18 34 tan $ 0.325 0.675 Section: A - A', Plane I1 Unit Weight, pcf 120 120 Area Weight of Slide Segment Segment Plane sin a (Ft2) (Kips/LF) Angle 3 833 100.0 15 0.259 4 490 58.8 15 0.259 5 1798 215.8 7 0.122 6 1056 126.7 7 0.122 7 315 37.8 55 0.819 Driving Normal Length cos a Force Force (Feet) W Sin a W Cos a 0.966 25.9 96.6 92 0.966 15.2 56.8 51 0.993 26.3 214.2 61 0.993 15.4 125.8 33 0.574 31.0 21.7 39 113.8 515.0 ECL+EWcosatanq ECL+(EWcos a—KEWsin a)tan 0 F.S. = F.S. _ E W sin a EWsina+KEWcosa 67.7 + 174.9 67.7 + 167.7 113.8 191.0 242.6 235.5 = = 2.13 = = 1.23 113.8 191.0 Geotechnical Engineering Investigation No. 3 Flying Mane Road Rolling Hills, California (K= 0.15) Project No. 315C-091 Plate 4A - R COASTLINE GEOTECHNICAL CONSULTANTS SLOPE STABILITY CALCULATIONS Parallel Cross Shear Strength Bedding Bedding 'Cohesion, psf 220 400 'Friction Angle, 0 18 34 'tan 0 0.325 0.675 Section: A - A', Plane III (Unit Weight, pcf 120 120 Segment Area (Ft2) 3 833 4 490 5 1798 6 1056 8 1020 9 296 Surcharge Weight of Slide Segment Plane sin a cos a (Kips/LF) Angle 100.0 15 0.259 0.966 58.8 15 0.259 0.966 215.8 7 0.122 0.993 126.7 7 0.122 0.993 122.4 7 0.122 0.993 35.5 55 0.819 0.574 7.2 7 I 0.122 0.993 Driving Normal Force Force W Sin a W Cos a 25.9 15.2 26.3 15:4 14.9 29.1 0.9 96.6 56.8 214.2 125.8 121.5 20.4 7.1 127.7 642.3 Length (Feet) 92 51 61 33 34 37 0 ECL+EWcosatan0 ECL+(EWcos a-KEWsin a)tan 0 F.S. = F.S. _ E W sin a EWsina+KEWcosa 74.4 + 215.8 74.4 + 208.1 127.7 224.1 290.2 = 2.27 _ 282.5 1.26 127.7 224.1 Geotechnical Engineering Investigation No. 3 Flying Mane Road Rolling Hills, California (K= 0.15) Project No. 315C-091 Plate 5A - R COASTLINE GEOTECHNICAL CONSULTANTS SLOPE STABILITY CALCULATIONS Parallel Cross Shear Strength Bedding Bedding (Cohesion, psf 220 400 Friction Angle, 0 18 34 tan 0 0.325 0.675 Section: A - A', Plane IV Unit Weight, pcf 120 120 Area Weight of Slide Segment Segment Plane (Ftz) (Kips/LF) Angle 3 833 100.0 15 4 490 58.8 15 5 1798 215.8 7 6 1056 126.7 7 10 1080 129.6 7 11 255 30.6 55 Surcharge 7.2 7 sin a cos a 0.259 0.259 0.122 0.122 0.122 0.819 0.122 0.966 0.966 0.993 0.993 0.993 0.574 0.993 Driving Normal Force Force W Sin a W Cos a 25.9 15.2 26.3 15.4 15.8 25.1 0,9 96.6 56.8 214.2 125.8 128.6 17.6 7.1 124.6 646.6 Length (Feet) 92 51 61 33 42 34 0 ECL+EWcos atan 0 ECL+(EWcos a-KEWsin a)tan 0 F.S. = E W sin a F.S. E W sin a+ K E W cos a 75.0 + 216.2 75.0 + 208.8 124.6 221.6 291.2 = 2.34 _ 283.8 = 1.28 124.6 221.6 (K= 0.15) Geotechnical Engineering Investigation Project No. 315C-091 No. 3 Flying Mane Road Rolling Hills, California Plate 5A - R COASTLINE GEOTECHNICAL CONSULTANTS Cuy o/ /20fA JhI% July 19, 1990 Dr. Michael Weller 3 Flying Mane Road Rolling Hills, CA 90274 INCORPORATED JANUARY 24, 1957 NO. 2 PORTUGUESE BEND ROAD ROLLING HILLS, CALIF. 90274 (213) 377-1521 FAX (213) 377.7288 SUBJECT: ZONING CASE NO. 429; Request for Site Plan Review for residential additions Dear Dr. Weller: Pursuant to Section 17.32.090 (enclosed) of the Rolling Hills Municipal Code, this letter shall serve as official notification that the above -stated Zoning Case application was reviewed by the Planning Commission at their regular meeting of July 17, 1990. At that meeting, the Planning Commission voted to approve the request for the Site Plan Review for residential additions. The Planning Commission's decision will be reported to the City Council at their regular meeting on August 13, 1990. The decision of the Planning Commission may be appealed pursuant to Sections 17.32.140 and 17.32.150 (enclosed) of the Municipal Code. A copy of Resolution 614, establishing the fee for filing an appeal, is also enclosed for your information. Should you have any questions regarding this matter, please contact this office. Sincerely, CITY OF RObLING HILLS Ray Ramada Principal Planner Encls /jr cc: Mr. Don Thursby, Architect Peggy Minor, RHCA Manager City .1) leoffiny JUL TO: Dr. Michael Weller 3 Flying Mane Road Rolling Hills, CA 90274 FROM: CITY OF ROLLING HILLS INCORPORATED JANUARY 24, 1957 NO. 2 PORTUGUESE BEND ROAD ROLLING HILLS, CALIF. 90274 (213) 377-1521 FAX: (213) 377-7288 The plan for: Site Plan RPvi Pw for prnpncPrt adrl; ti r o Applicant: Dr, Michael Weller Address: 3 Flying Mane Road, Rolling Hills, CA 90274 (a) Complies with City Zoning requirements (b) Needs Variance ( ) Contact City for application and submittal requirements. (c) Needs Conditional Use Permit Contact City for application and submittal requirements. (d) Needs Site Plan Review Contact City for application and submittal requirements. (e) xx Other (see below) The Planning Commission at their regular meeting held June 19, 1990, continued the above -stated application to an adjourned meeting to be held Saturday,'June 30, 1990, at 7:30 A.M., So as to conduct a field inspection of the Site and surrounding properties. The property must be prepared to exhibit the proposed project, and the owner and/or representative should be present. Should you have any further questions, please contact the undersigned at this office. June 21.. 1990 Ray Hamada Principal Planner CC: Mr. Don Thursby Mr. Edward Beall, Edward, Carson Beall & Assoc. • EDWARD CARSON BEALL, A.I.A. AND ASSOCIATES INTERIORS EDWARD CARSON BEALL, A.I.A., A.I.C.P. GEORGE C. SHAW, A.I.A. FRANK J. BALOGH, A.I.A. MILES E. PRITZKAT, A.I.A. JOHN M. HORI, A.I.A. WON NA NG, A.I.A. DAVID MCKINNEY, A.I.A. SUSAN R BEALL, A.S.I.D. June 18, 1990 ARCHITECTURE PLANNING MEMBERS OF THE AMERICAN INSTITUTE OF ARCHITECTS Project: Dr. and Mrs. Michael Weller #3 Flying Mane Road Rolling Hills, California 90274 ADDENDUM TO SITE PLAN REVIEW APPLICATION #429 Correction of Building Pad area noted on plans: Existing Building Pad = 7,238 square feet 23 72 7 HAWTHORNE BOULEVARD TORRANCE, CALIFORNIA 90505 (213) 378 - 1280 FAX (213) 375-9530 Georae DeVries Consulting Geologist 4520 E. Slauson Ave., Maywood, California 90270 — (213) 771-3046 / (213) 596-0467 May 4. 1990 Project No. 1183-030 Dr. and Mrs. Michael Weller c/o Coastline Geotechnical Consultants 1446 , W. 'i'78th St. Gardena, CA 90248 Subject: Preliminary Engineering Geology Investigation Proposed Residential Addition No. 3 Flying Mane Rd. Rolling Hills, CA Dear Dr. & Mrs. Weller, This report presents the results of an engineering geology investigation performed on the referenced lot. It is prepared in conjunction with a soils engineering investigation by Coastline Geotechnical Consultants, Inc. dated April 20, 1990. The purpose of this investigation was to evaluate the existing geological conditions as they would apply to the contemplated development and to offer suggestions and recommendations for mitigating potential hazards if fund to be present. In addition, conclusions concerning the feasibility of the proposed development from the geological standpoint were formulated. While no detailed plans were available at the time of the investigation, it is understood the proposed development will consist of two, one-story additions to the west and north portions of the existing residence. The general location of the site is shown on Plate 1 while the site geologic map is presented in Plate 2 (A-B). The investigation consisted of surficial field mapping, subsurface•explor'ation of seven' (7)'hand-excavated test pits, analysis of collected data, as. well as a review of pertinent geologic data for the vicinity, and preparation of this report. Field investigations were conducted March 8 & 9, 1990. The results of the study are present in Plates 2 through 9: Geologic Map, Geologic Cross Section, and subsurface exploration logs. Registered Geologist Certified Engineering Geologist ) 1183-030/ May 4, 1990 • Michael.Weller/Rolling Hills SITE CONDITIONS Location and Topography Page 2 The subject site is located on the west side of Flying Mane Rd. south of the junction with Southfield Dr. in the City of Rolling Hills, Los Angeles, County. The lot is irregular in shape measuring approximately 350 feet by 150 feet. The lot is bounded on the north, south, and west by developed lots and on the west by Southfield Dr. and an undeveloped lot along an existing draih'age (Plate 2B). From .a nearly level building pad west of Flying Mane Rd., the lot. descends an approximately 25 degree slope to Southfield Dr.. From Southfield Dr. the slope continues approximately 150 vertical feet to the drainage _`below. Topographic relief on the site is approximately 100 feet, while the relief on the overall slope is on the order of 250 feet. The site location and topography axe depicted on Plates 1 and 2 (A-B). Drainage and Groundwater Site drainage is comprised of essentially sheet flow runoff from precipitation derived primarily within parcel boundaries. Drainage off site is predominately to the west where it flows off -site to Southfield Dr.. Ground water was not encountered in any of the excavations and none is anticipated. No active springs or surface seeps were observed during this investigation. Geology Fill: The western portion of the building pad consists of variable thickness of fill material over natural soil and bedrock. Measured fill thicknesses ranged from 2.5 to 6.5 feet in depth. The fill material is typically firm, moist, mottled brown and yellow -brown Silty Clay with locally abundant siltstone clasts. Locally a 0.5 foot layer of fine-grained sand was present as a landscape fill. Soil: A soil layer was observed above the bedrock in all the test pits except the two footing excavations (TP-1 & TP-2). The soil ranged from 0.5 foot to 4 feet thick. The soil is generally stiff, moist, dark -brown to black Silty Clay with some siltstone clasts. The lower contact is generally gradational. Bedrock. Monterey Formation (Tma): The site is underlain by sedimentary rocks of the Altamira Shale Member of the Miocene i 1i83-030/ May 4, 1990 Michael Weller/ Rolling Hills Page 3 Monterey Formation. This unit was observed in all test pits except.TP-1 & TP-2. The unit was also observed in outcrop along road cuts along Southfield Dr. and Flying Mane Rd. The Altamira Shale Member in the site and vicinity consists of predominantly light -gray to medium yellow -brown, moderately hard, moderately ;D well -bedded, poorly fractured Diatomaceous Siltstone with locally some interlayered dolomitic and siliceous siltstone layers. Bedding attitudes are generally consistent where observed on the site with some local variation. The bedding attitudes observed on the site near the proposed additions generally dip 3 apprpxl mately 20 to 30 degrees (range from 10 to 34) to the south and southwest. The attitudes observed are generally neutral to the s.lope'some local component of outdip (Plate 3). Bedding attitudes observed in the road cuts in the site vicinity are generally similar with a slightly more westward component of dip. Bedrock observed in test pits TP-6 & TP-7 showed a significant range in bedding attitudes. The bedrock was poorly bedded, locally folded and locally fractured. The material appears to have been subject to fracturing and folding due to local faulting or intraformational deformation. No fault was observed in the test pits. FAULTS The site does not lie within an Alquist-Priolo Special Studies Zone and no active faults were observed during this investigation. The nearest active fault, the Newport -Inglewood, is located approximately 10 miles to the northeast. The potentially active Cabrillo and Palos Verdes Fault Zones are located approximately 0.5 and 3 miles, respectively, to the north and northeast. Recently, a northwest trending subsurface fault zone has been postulated to extend below the Palos Verdes Hills. A similar subsurface fault zone is postulated to extend below the Whittier Narrows area and movement on this fault is believed to be the cause of the October 1, 1990 earthquake in that area. The site is, therefore, subject to ground shaking typical of the Southern California area and, thus any construction should conform to seismic design provisions of the Uniform Building Code. The bedrock observed in test pits TP-6 & TP-7 displayed features which may be indicative of nearby local faulting. No fault plane was observed in the test pits TP-6 or TP-7 and the fractures and folding observed in the two test pits was not observed in any of the other test pits. No active or potentially active faults are known to exist on the site. a 1183-030/ May 4, 1990 Michael_ Weller/ Rolling Hills SLOPE STABILITY Page 4 No signs of surficial or deep seated instability were observed on the property. Creep, which is the nearly imperceptible movement of surficial soils down -slope due to the force of gravity, was observed on the slopes, and is believed to extend to the depths of fill and/or soil material. CONCLUSIONS AND RECOMMENDATIONS In the opinion of the undersigned, the proposed development, as contemplated, is feasible from the engineering geology standpoint, provided adherence is given to the recommendations of this and other related reports,;; Additionally, no adverse effects from geologic hazards of landslide settlement or slippage are anticipated for the site or adjacent properties given the same adherence to. the stated recommendations. 1. Foundation systems will be embedded in accordance with the soil engineering report. 2. The stability of the site shall be determined by the soil engineer. The factor -of -safety should meet regulatory agency requirement. 3. Bedrock units appear capable of supporting the structural loads and it is recommended that all foundations, founded in this material extend a minimum depth to be determined by the soil engineer. As a minimum, all foundations should extend below any weathered bedrock into competent material. 4. All roof, pad, and site drainage shall be conducted to appropriate drainage systems via non -erosive devices. 5. The site is subject to ground shaking typical of the Southern California area and any'construction should conform to seismic design provisions of the Uniform Building Code. 6. Inspection of all foundation excavations shall be performed by the engineering geologist to verify that they are founded in competent geologic materials. REMARKS This investigation was made in accordance with generally accepted engineering geology procedures and within the limits prescribed ao ) ) 1183-030/ May 4, 1990 Michael Weller/ Rolling Hills Page 5 -by the client.', No other warranty, expressed or implied, is made as to the professional advice included in this report. Although no significant variations in bedrock or soil conditions are anticipated, it conditions are encountered during future restoration work and these conditions appear to be different from those disclosed by this preliminary report, this office shall be notified so as to consider the need for modification. While caving was not observed within the excavations, other excavations may act differently and may require shoring during future restoration work. In this regard, all shoring and bracing if nece$:sary, shall conform to current standards of the Industrial Accident.Commission of the State of California nd other pubic agencies having jurisdiction. This report has been prepared for the exclusive use of Dr. and Mrs. Michael Weller and their authorized representative. It shall not be transferred to, or used by; a third party, to another project, or applied to any other project on this site, other than described herein, without consent, and/or thorough review by this office. Should this project be delayed beyond a period of two years after the date of this report, the site and report shall be reviewed by this office to consider possible changed conditions. This report is subject to review by controlling public agencies having jurisdiction. Respectfully submitted, eorge DeVries CEG 1141 GDV:ga Distr: Addressee (5) Coastline Consultants'(1) Attachments: Plates 1 thru 9 from USGS San Pedro ICINI T Y MAF' & Torrance Quadrangle Map Michael Weller # 3 Flying Mane Rd. Rolling Hills, CA SCALE 1:24,000 Proj. N2 1183-030 Plate e• 1=1 g D et V 1-, ez. — C E ta 1 t. ing es, al 1 al g ss 3 3 EXF'1—ANIAT' I ON Tma - Monterey Formation Altamira Shale Member 4-.4-AMM - Geologic Contact (approx. located) - Strike & Dip of Bedding - Approx. Test Pit Location REFERENCE PLAN ROOF PLAN BY FULLER & KUFUS UNDATED 1. 1. / / ' / 2 ////2(11/ /////F 2 • // till /I/. 10 /,/, PROPOSED—) A D9ITION 34 • • Fill overima • / , , „- , / / /1 ",, .,.,._,,N,--\-- j/ /// - / i • ..1 '' ;1, '40i///, '''-- ..- //// r 7 45 / / / . i / : • f , i ./.. . / / / - / ., . I / ,.. , -: --- . ' / -- x v S I T E . —1-- -/ • - -:---,-'- /- .,,----."..,-- 7---- GEOLOGIC . MAP .- - - - - ----- . , . \.0. 43 0 c) \ - Michael_Weller- 0 No.':3 Flying Mane Rd 0 . Rolling Hills; CA EXISTING RESIDENCE SCALE: IhI=201 DATE : APR 90 • APPROVED BY: 1183- 0 30 George DeVries Consulting Geologist 0• cc 0 z LL 2 IDRAWN BY JG IREVISED DRAWING NUMBER 2 A 11 XI-? Amim PAINTED ON Na.100011 CLEARPRINT• - rr • /' ' ,, / ,/ ; '1' - • / • • /e% %'' i• , /r • I {;� - t ; : ' , -`L \ 4 .� f Ir `� t L - 't :l • • ‘ r i rr •I i; :: IIr `o_ t =? N �, f1 1 " ry. >` s L t�: �Y t j i; l • \01`1, tt. . Oil L r \• ; •t• \ _X.l .t o l l �'- ' ..y 07er{ ' `-ter - ' \il • T� �1 • `«�y► r - ( 11ia •;z1 - \:1 '—j / / _i -- 1,1.:7 1 ,—.T., It 1 i .„,:z.'` '-� i / / r • / . • /• - \A l 1 I• • t• 1 .1.• ., • 1 • S�`]� �. / / / , / ' / • - v - y r., f i . ;SCALE 1":100 :Q` . f`., .t (l �: ( L, ! ' i _._ .` t • - • A .`\ • i .t • i • ' ! I: r' :../ ti. • �+_ -.RE'FERENCE: -. i 1 :am VICINITY IN. `„`,\ DATE: APR 90 • • ',= /l ' ! i✓:- :J • /_ / - �-' / —''` / ,- / ,.. / i /' i • / ,/. / -, .:• ,/' ... T.0P06.RAP•H C P L A N 1 • • s., I ''F-RQV(DED',8Y. SOUTH'B ',EN GIN EER-1rgc• - GEOLOGIC MAP Michael Weller. No. 3 Flying Mane Rd. Rolling Hills, CA SCALE: 1 fl= 1 00l APPROVED BY: 1183-030 Georae DeVries Consulting Geologist • r DRAWN BY REVISED IDRAWING NUMBER JG • 1) ) _ G E O L O G I C CROSS S E C T I O N Q 3NVIN DNIAld 1 II IF LC) ~ Q Co 'lia 013Id Hlnos LL 0 (133d) NOIIVA313 SECTION A -A' 0 0 ' I 0 0 0 0 0 0 0 0 0 to d to N a) XI 0 N r td • N 1~ H W ,0 • rd w 4J W E A +�cc! We O 4-1 a • g El I I I cd H �C 0 N o rd II m Michael Weller Proj. N ° 1183-030 No. 3 Flyign Mane Rd. Rolling Hills, CA Plate 3 Ge?or$e Dee•Vriets—Corzmul tirlg G��a 10gi t •S SUBSURFACE EXPLORATION LOGS DEPTH INTERVAL DEPTH ATTITUDES DESCRIPTION TP-i 0.0-2.0 TP-2 0.0-2.0 Fill: Sandy Clay, mottled Tight and dark brown, firm, moist, some angular siltstone clasts; existing footing extends to approximately one foot depth TD=2.0 No water, No caving Fill: Sandy Clay, mottled light and medium brown, firm, moist, some angular ',siltstone clasts; existing footing extends to approximately one foot depth @1.0 -becomes black sandy and silty clay TD=2.0 No water, No caving SUBSURFACE EXPLORATION LOOS DEPTH INTERVAL DEPTH ATTITUDES DESCRIPTION TP-3 0.0-0.5 0.5-6.5, +_'; 6.5-9.0 9.0-12.0 )• ) N7OW, 90-70N N20E, vert. @10.0 N7OW, 10S @11.0 N55W, 22S TD=12.0 Landscape Fill: Sand, fine grained, some silt, medium brown, damp to moist, loose to medium dense, contact sharp and horizontal Fill: Silty Clay, dark brown, firm, moist; some angular siltstone cl:asts, abundant in upper 2 feet, clasts,are platy and blocky; abundant roots in upper 4 feet Soil: Silty Clay, black, stiff, moist; some angular siltstone clasts; upper and lower contacts gradational and irregular Bedrock (Tma): Monterey Formation, Altamira Shale Member; Diatomaceous Siltstone, light gray and medium yellow brown, hard, moderately bedded, poorly fractured, some roots and soil pods in upper l foot -joint attitudes - bedding attitude - bedding attitude No water, No caving PLATE 5 SUBSURFACE EXPLORATION LOGS, DEPTH INTERVAL DEPTH ATTITUDES DESCRIPTION, TP-4 0.0-2.5 2.5-6;.5% 6.5-10.0 N75W, 90-80N N20E, vert. Fill: Silty Clay, mottled dark brown and yellow brown, firm, moist, roots; abundant siltstone clasts, angular, platy; lower contact gradational;. lower contact gradational and approximately parallel to slope ( N15E, 20W) Soil: Silty Clay, black, stiff,, moist;_ some angular siltstone clasts, clasts are platy and blocky; lower contact is very irregular over 0.5 to 1.0 foot and approximately parallel to slope ( N15E, 25W) Bedrock (Tma): Monterey Formation, Altamira Shale Member; Diatomaceous Siltstone with some minor interbedded dolomitic siltstone, light gray to medium yellow brown, dry to damp, hard, moderately well bedded, poorly fractured; some soil pods and rodent burrows in upper i to 2 f eet • -joint attitudes, poorly developed @7.0 N5OW, 20S -bedding attitude @8.0 N5OW, 20S N15W, 20W -bedding attitude, some minor folding and local variation @9.0 N35W, 20W/ -bedding attitude TD=10.0 No water, No caving PLATE 6 44. ) ) SUBSURFACE EXPLORATION LOGS DEPTH INTERVAL DEPTH ATTITUDES DESCRIPTION TP-5 0.0-0.5 0.5-4.0 "; 4.0-7.0 7.0-11.5 Landscape Fill: Sand, fine grained, some silt, medium brown, damp to moist, loose to medium dense, contact sharp and horizontal Fill: Silty Clay, mottled brown and yellow brown, firm, damp to moist, some roots; some angular siltstone clasts, less abundant in lower 2 feet; lower contact , gradational with slight dip to west ( 10W) Soil: Silty Clay, black, stiff, damp; some angular siltstone clasts; lower -contact gradational and slightly irregular, slight west dip ( 10W) Bedrock (Tma): Monterey Formation, Altamira Shale Member; Diatomaceous Siltstone, some dolomitic and siliceous siltstone layers, light gray to yellow brown, very hard, moderately bedded, very poorly jointed; some roots and soil pods in upper 2 feet _ N7OW, 90-80N -joint attitudes, approximately . N-S, 90-80E perpendicular to bedding @9.0 N3OW, 27W @10.0 N40W, 34W TD=11.5 - bedding attitude - bedding attitude No water, No caving PLATE 7 _) SUBSURFACE EXPLORATION LOGS, DEPTH INTERVAL DEPTH ATTITUDES DESCRIPTION, TP-6 0.0-0.5 0.5-7.0 i 1; 04.0 NI5W, 40W @4.5 N35W, 35W 05.5 N3OW, 45W @6.0 Soil: Silty Clay/Clayey Silt, dark brown, firm, damp to moist; some angular and blocky siltstone clasts; soil poorly developed; lower contact gradational, approximately parallel to slope Bedrock (Tma): Monterey Formation, Altamira Shale Member; Diatomaceous Siltstone with interbedded dolomitic and siliceous siltstone, gray to yellow brown, dry to damp, hard; highly fractured and weathered in upper 1 to 2 feet, becomes moderately fractured below 2 feet; some "local folding and variation of bedding predominantly along north side of test . pit, local over -steeping of bedding may indicate local fault in vicinity -bedding attitude -bedding attitude -bedding attitude -poorly bedded below 6 feet, some zones of highly fractures/ brecciated bedrock along north side of test pit, approximately parallel to shear zones noted in test pit TP-7 (N3OW, 80S), appears to be a fault zone of approximately northwest orientation TD=7.0 No water, No caving PLATE 8 SUBSURFACE EXPLORATION LOGS DEPTH INTERVAL DEPTH ATTITUDES DESCRIPTION TP-7 0.0-1.0 1.0-6.0 i. % N60E, 80-70N N3OW, 80S @3.0 N50E, 40S @4.0 N7OW, 32S TD=6.0 Soil: Silty Clay/Clayey Silt, dark brown, firm, damp to moist; some angular and blocky siltstone clasts; lower contact gradational ( E-W, 25N) Bedrock (Tma): Monterey Formation, Altamira Shale Member; Dolomitic and Siliceous Siltstone with some interbedded diatomaceous siltstone, light to medium brown, hard, well bedded, moderately fractured; some weathering and soil pods in upper 1 foot - joint attitudes, approximately perpendicular to bedding -N3OW, 80S joint set displays some shearing and local offset; some gypsum fracture filling - bedding attitude - bedding attitude - No water, No caving PLATE 9