none, Install ground mounted solar p, ApplicationBuilding Permit Fee $
Plan Check No.
The approval of this plan, drawings or specification
by the Rolling Hills Community Association shall
not be held to permit or to be an approval of the
violation of any of the building regulations adopted
by the association or be an approval of the City of
Rolling Hills or of State law.
No. 6436
The
ROLLING HILLS COMMUNITY ASSOCIATION
BUILDING PERMIT
Date (i2I 121
4 V
�
rchitectural Committee of this Association has approved the plans and specifications for the construction
�\OW' O C v J\AC v®)�
of
olikkoFLQ ovx, e'` d . on Lot No. Tract C%P
for esneL-W.ci, a Address Savvy\
Sonvnc
OWNER AGREES: @‘ 0°C) 3q0-
1. To conform to all regulations and restrictions of the Association and all construction work will be in
accordance with the plans bearing stamp of approval of the Association.
2. No changes will be made without first securing written approval of Architectural Committee.
3. To obtain a City permit and conform to the Building Code of the City of Rolling Hills.
4. To call the Association Inspector for the following inspections:
(1) Staking (2) Grading (3) Foundation (4) Framing (5) Final
5. To do no grading, paving, construction or planting of any kind in easements.
6. TO PAINT ALL EXTERIOR SURFACES WHITE USING APPROVED WHITE PAINT WHICH
CONTAINS NO TINTING; trim color to be submitted for approval.
7. To not occupy residence until final approval is given.
"This Building Permit is issued by the Architectural Committee and
is an approval of the exterior and appearance of residence only. The
Association makes no representation as to stability of the land or
legality of the building site."
Owner's signature
ROLLING HILLS COMMUNITY ASSOCIATION
By
This Permit is Valid for One Year
Homeowner's Copy — Please keep for your records
Form BP-5
AHJ NOTES
ALL CONDUIT TO RUN ON EXTERIOR
OF HOUSE UNLESS OTHERWISE NOTED
OCCUPANCY: R-3
CONSTRUCTION TYPE: VB
UNSPRINKLERED
CITY OF ROLL]NG PILLS
Approved by:
PLANNINDFP
/ /2 l 17
Date
— Soles ''"�'� - Sw v „dt ✓�'
— .Lle A'S CA.(
to \ 0v•
�4r 0.r0 .
5o
PLAN SET LEGEND
MSP
SUB
AC
DC
SLC
EN
M
PM
INV
MAIN SERVICE PANEL
SUB SERVICE PANEL
AC DISCONNECT
DC DISCONNECT
SOLAR LOAD CENTER
ENPHASE AC SOLAR PV
COMBINER BOX
PV MONITORING METER
CITY PERFORMANCE
METER
INVERTER
JB JUNCTION BOX
CB COMBINER BOX
UM/M
RS 1 RAPID SHUTDOWN BOX
UTILITY METER &
MAIN BREAKER ONLY
(E)
(N)
EXT
INT
EMT
RMT
VOC
VMP
ISC
IMP
NTS
ABBREVIATIONS
EXISTING
NEW
EXTERIOR
INTERIOR
ELECTRICAL METALLIC TUBING
RIGID METALLIC TUBING
VOLTAGE OPEN CIRCUIT
VOLTAGE AT MAX. POWER
SHORT CIRCUIT CURRENT
CURRENT AT MAX. POWER
NOT TO SCALE
VICINITY MAP
ry�
'QrT
Inspectors Pacific
0
-J
PROJECT
SITE
ann's Trail . - Joeaan's Trag
6rryre Tr�U
rn
PROJECT INFORMATION
Hanwha Q CELLS Q.PEAK
85 X 290 W BLK-G4.1 290
GROUND MOUNTED SOLAR PHOTOVOLTAIC
MODULES
Enphase Energy
85 X 250 W M250-60-2LL-S2X
SYSTEM SIZE:
ARRAY AREA:
24.65
0 kW DC STC, 20.506 kW AC
1530 SF
AHJ: CITY OF ROLLING HILLS
APN: 756-700-6008
KARL SCHMIDT
5 CHESTERFIELD ROAD
ROLLING HILLS, CA 90274
APPLICABLE CODES
ALL WORK TO COMPLY WITH
THE FOLLOWING CODES:
2016 CA BUILDING CODE
2016 CA RESIDENTIAL CODE
2016 CA MECHANICAL CODE
2016 CA ELECTRICAL CODE
2016 CA GREEN CODE
2016 CA PLUMBING CODE
2016 CA ENERGY CODE
2016 CA FIRE CODE
SHEET INDEX
PV-1 PROJECT INFORMATION
PV-1A SITE PLAN, HOUSE PHOTO
PV-2 ARRAY PLAN
PV-2A STRUCTURAL DETAILS
PV-3 ELECTRICAL LINE DIAGRAM &
ELECTRICAL CALCULATIONS
PV-3A ELECTRICAL NOTES
PV-4 & 4A REQUIRED SIGNAGE
Solar Photovoltaic System
ISSUED FOR PERMIT
KARL SCHMIDT
PROJECT INFORMATION
5 CHESTERFIELD ROAD
ROLLING HILLS, CA 90274
(310) 346-7427
PV-1
Freedom Forever
43445 Business Park Drive
Suite 110
Temecula, CA 92590
Schmidt, Annie and Carl
5 Chesterfield Rd
Rolling Hills CA 90274
19th August 2019
OVERVIEW
Current solar array angle and location are causing reflection from the sun and affecting a
neighboring property during a certain time of year.
SPECIFICATIONS
Freedom Forever will modify the design and installation in order to eliminate the glare coming
from the solar array. The modification will mimic another array that is part of this same HOA. The
array will have a staggered/shingling effect that will produce a greater angle directed away from
the neighbor. This will also break up the array so it has less surface area for the reflection.
Brad Ouellette
Design and Quality Control Manager
Freedom Forever
AU( [ U 2019
holiing Hills
r i inet4AV4