629, Construct Hobby shop/Pool hous, Staff ReportsDATE:
TO:
ATTN:
FROM:
SUBJECT:
• •
eiiy 0/ Polk" _WA
JUNE 25, 2001
HONORABLE MAYOR AND MEMBERS OF THE CITY COUNCIL
CRAIG R. NEALIS, CITY MANAGER
YOLANTA SCHWARTZ, PRINCIPAL PLANNER
RESOLUTION NO. 2001-11: A RESOLUTION OF THE
PLANNING COMMISSION OF THE CITY OF ROLLING HILLS
GRANTING SITE PLAN REVIEW APPROVAL TO PERMIT
GRADING AND CONSTRUCTION OF A NEW SINGLE FAMILY
RESIDENCE WITH A POOL, POOL HOUSE AND A STABLE,
AND A CONDITIONAL USE PERMIT TO CONSTRUCT A POOL
HOUSE AT A VACANT SITE AT 4 PINE TREE LANE, IN
ZONING CASE NO. 629.
INCORPORATED JANUARY 24, 1957
NO. 2 PORTUGUESE BEND ROAD
ROLLING HILLS, CALIF. 90274
(310) 377-1521
FAX: (310) 377-7288
E-mail: cityofrh@aol.com
Agenda Item No.: 4A
Mtg. Date: 6/25/01
BACKGROUND
1. The Planning Commission adopted Resolution No. 2001-11, which is attached,
on June 19, 2001 at their regular meeting granting a request for a site plan
approval to construct a new single family residence, which requires grading a
pool, pool house, and a stable, and a Conditional Use Permit to construct a pool
house. The vote was 5-0.
2. The Planning Commission viewed a silhouette of the proposed project at the
site on Saturday, May 5, 2001, and held public hearings on April 17, 2001 and
May 15, 2001.
3. The applicant is requesting Site Plan Review approval for the construction of a
new 5,840 square foot residence with 4,720 square foot basement, 1,428 square
foot garage, 800 square foot pool, 800 square foot pool house, 816 square foot
stable and a service yard at an existing vacant lot. A 1,375 square foot basketball
court exists on the site. The basketball court will be demolished, and therefore is
not included in the net lot and pad coverage calculations. A Conditional Use
Permit review is also requested for the construction of the pool house. The
proposed construction requires grading. Site Plan Review criteria and house/lot
size comparison of nearby residences is attached.
ZC No.629 1
Printed on Recycled Paper.
• •
4. The proposed pool house will be located on a secondary building pad, situated
below the residential pad, to the north of the residence. Pursuant to Section
17.16.210 of the Zoning Ordinance, cabanas and detached recreation rooms
require conditional use permit. Staff determined that based on the type of use
proposed and its location, the proposed pool house falls under the definition of a
cabana under the City's Zoning Ordinance. No sleeping quarters or kitchen or
other cooking facilities are permitted in cabanas or detached recreation rooms.
These conditions are included in the conditions of approval.
5. Grading for the project will require 6,200 cubic yards of cut soil and 6,200 cubic
yards of fill soil, which will be balanced on site.
6. The property is zoned RAS-2, and the net lot area is 4,377 acres. The property is
developed with dense trees and bushes, which will remain, except where the
•
development is proposed. Proposed are two new construction pads totaling
37,440 square feet.
7. The structural net lot coverage proposed is 9,780 square feet or 5.1%, which
includes the residence, garages, pool, pool house, stable, and the service yard,
(20% permitted); and the total lot coverage proposed including the structures
and paved areas is 21,400 square feet or 11.2%, (35% permitted).
8. Building pad coverage on the 26,800 square foot residential building pad is 7,364
square feet or 27.5 %. Building pad coverage on the 10,640 square foot pool, pool
house and stable pad is 2,416 square feet or 22.7%. The two pads total 37,440
square feet and will have 26.1% coverage.
9. Disturbed area of the lot will be 34.0%, (40% permitted) of the net lot area.
Disturbance includes any remedial grading (temporary disturbance), any graded
slopes and building pad areas, and any nongraded area where impervious
surfaces will remain or are proposed to be added.
10. In February of 2001 the original 2,882 square foot house, garage and a pool were
demolished. The original house was built in 1937. The applicant is proposing to
utilize the existing apron and the existing driveway, therefore a review by the
Traffic Commission is not required. However, the driveway will be widened to
15 feet. Due to the distance from the road to the proposed residence, the Fire
Department will require that the residence be equipped with a sprinkler system.
According to applicant's representative, the driveway was reviewed and
approved by the Fire Department.
11. Access to the proposed stable will be by a 10-foot wide gravel driveway, located
along the westerly side of the house, with a slope not to exceed 16%.
12. The project has been determined to be categorically exempt pursuant to the
California Environmental Quality Act (CEQA).
RECOMMENDATION
It is recommended that the City Council receive and file Resolution No. 2001-11.
ZC No.629 2
•
Zoning Case No. 629
SITE PLAN REVIEW II
RA-S- 2 ZONE SETBACKS
Front: 50 ft. from front easement line
Side: 35 ft. from property line
Rear: 50 ft. from property line
STRUCTURES
(Site Plan Review required if size of
structure increases by at least 1,000 sq.ft.
and has the effect of increasing the size of
the structure by more than 25% in a 36-
month period).
STRUCTURAL LOT COVERAGE
(20% maximum)
TOTAL LOT COVERAGE
(35% maximum)
RESIDENTIAL BUILDING PAD
COVERAGE
STABLE /POOL BUILDING PAD
COVERAGE
TOTAL BUILDING PAD COVERAGE
(Guideline maximum of 30%)
GRADING
Site Plan Review required if excavation
and/or fill or combination thereof that is
more than 3 feet in depth and covers more
than 2,000 sq.ft.) must be balanced on
site.
DISTURBED AREA
(40% maximum; any graded building pad
area, any remedial grading (temporary
disturbance), any graded slopes and
building pad areas, and any nongraded
area where impervious surfaces exist.)
STABLE (min. 450 SQ.FT.
& 550 SQ.FT. CORRAL)
STABLE ACCESS
ROADWAY ACCESS
VIEWS
PLANTS AND ANIMALS
ZC No. 629
EXISTING
VACANT LOT
Residence
Garage
Swim Pool/Spa
TOTAL
Existing driveway off Pine Tree
Lane
N/A I Planning Commission will review.
N/A I Planning Commission will review.
II PROPOSED
SINGLE FAMILY RESIDENCE,
POOL, POOL HOUSE & STABLE
Residence 5,840 sq.ft.
Garage 1,428 sq.ft.
Swim Pool 800 sq.ft.
Stable 816 sq.ft.
Pool House 800 sq.ft.
Service yard 96 sq.ft
Basement 4,720 sq.ft.
ITOTAL (excluding 9,780 sq.ft.
basement
15.1%
27.5%
122.7%
126.1 %
6,200 cubic yards cut
6,200 cubic yards fill
34.0%
1816 sq. ft. stable
550 sq. ft. corral
Accessed by a 10-foot wide trail
from the existing driveway
with a maximum slope to the stable
16%.
IExisting driveway off Pine Tree Lane
NEARBY
PROPERTIES
ADDRESS
3 Pine Tree
Lane
5 Pine Tree
Lane
6 Pine Tree
Lane
12 Upper
Blackwater
Canyon
8 Blackwater
Canyon
ZC No. 629
OWNER
Bailey
IUllrich
1Goldberg
Lodhie
I Ishak
AVERAGE
PROPOSED
RESIDENCE
(SQ.FT.)
4,720 I
4,286
6,148
7,614(Proposed
5,055
5,564
5,840
LOT SIZE
(NET)
223,027
208,217
57,064
3.23 acres
148,975
155,596
(3.57acres)
4.38
• •
RESOLUTION NO. 2001-11
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF
ROLLING HILLS GRANTING SITE PLAN REVIEW APPROVAL TO
PERMIT GRADING AND CONSTRUCTION OF A NEW SINGLE FAMILY
RESIDENCE WITH A POOL, A POOL HOUSE AND A STABLE, AND
GRANTING A CONDITIONAL USE PERMIT APPROVAL TO CONSTRUCT
A POOL HOUSE AT A VACANT SITE AT 4 PINE TREE LANE, IN ZONING
CASE NO. 629.
THE PLANNING COMMISSION OF THE CITY OF ROLLING HILLS DOES
HEREBY FIND, RESOLVE AND ORDER AS FOLLOWS:
Section 1. Applications were duly filed by Mr. Centofante with respect to real
property located at 4 Pine Tree Lane, (Lot 96-1-RH), Rolling Hills, CA requesting a Site
Plan Review to permit grading and construction of a new residence, a pool house, a
stable, and a pool at a vacant lot, and requesting a Conditional Use Permit to permit the
construction of a pool house.
Section 2. The Planning Commission conducted duly noticed public hearings
to consider the applications on April 17, 2001, May 15, 2001, and at a field trip visit on
May 5, 2001. The applicant was notified of the public hearings in writing by first class
mail. Evidence was heard and presented from all persons interested in affecting said
proposal and from members of the City staff and the Planning Commission having
reviewed, analyzed and studied said proposal. The applicant was in attendance at the
hearings.
Section 3. The Planning Commission finds that the project qualifies as a Class
3 Exemption (The State of CA Guidelines, Section 15303) and is therefore categorically
exempt from environmental review under the California Environmental Quality Act.
Section 4. Section 17.16.210(A)(2) of the Rolling Hills Municipal Code permits
approval for a pool house under certain conditions, provided a Conditional Use Permit
for such use is approved by the Planning Commission. The applicant is requesting
permission to construct an 800 square foot pool house on a secondary building pad
located to the north of the residential building pad. With respect to this request for a
Conditional Use Permit, the Planning Commission finds as follows:
A. The granting of a Conditional Use Permit for the construction of a pool
house would be consistent with the purposes and objectives of the Zoning Ordinance
and General Plan and will be desirable for the public convenience and welfare. The use
is consistent with similar uses in the community, and the area proposed for the pool
house would be located in an area on the property where such use will not dramatically
change. the existing configuration. of the lot. Section 17.16.040 of the Rolling Hills
Municipal Code permits detached pool houses in the RA-S-2 Zone with a Conditional
Use Permit.
• •
B. The nature, condition, and development of adjacent uses, buildings, and
structures have been considered, and the construction of a pool house will not
adversely affect or be materially detrimental to these adjacent uses, buildings, or
structures because the proposed pool house will be constructed at the central portion of
the lot and is a sufficient distance from nearby residences to insure that the pool house
will not impact the view or privacy of surrounding neighbors.
C. The project is harmonious in scale and mass with the site, the natural
terrain, and surrounding residences because the pool house will comply with the low
profile residential development pattern of the community and is located on a 4.9 acre
parcel of property that is adequate in size, shape and topography to accommodate such
use.
D. The proposed conditional use complies with all applicable development
standards of the zone district in which it is located because the 800 square foot size of
the pool house is within the 800 square foot maximum permitted and the pool house
does not encroach into any required setback areas.
E. The proposed conditional use is consistent with the portions of the Los
Angeles County Hazardous Waste Management Plan relating to siting and siting
criteria for hazardous waste facilities because the project site is not listed on the current
State of California Hazardous Waste and Substances Sites List.
F. The proposed conditional use observes the spirit and intent of Title 17 of
the Zoning Code by constructing a stable structure and adjacent corral that will be
located on the same building pad.
Section 5. Based upon the foregoing findings, the Planning Commission
hereby approves a Conditional Use Permit for the construction of an 800 square foot
pool house in accordance with the development plan dated May 2, 2001, and marked
Exhibit A in Zoning Case No. 629 subject to the conditions contained in Section 8 of this
resolution.
Section 6. Section 17.46.030 requires a development plan to be submitted for
site plan review and approval before any grading requiring a grading permit or any
building or structure may be constructed or any expansion, addition, alteration or
repair to existing buildings may be made which involve ' changes to grading or an
increase to the size of the building or structure by at least 1,000 square feet and has 'the
effect of increasing the size of the building by more than twenty-five percent (25%) in
any thirty-six (36) month period. With respect to the Site Plan Review application
requesting construction of the new house, pool house, pool, and stable at an existing
vacant lot, the Planning Commission makes the following findings of fact:
A. The proposed development is compatible with the General Plan, the
Zoning Ordinance and surrounding uses because the proposed structures comply with
the General Plan requirement of low profile, low density residential development with
sufficient open space between surrounding structures. The project conforms to Zoning
Code setback and lot coverage requirements. The lot has a net square foot area of
190,680 square feet. The proposed residence (5,840 sq.ft.), garage (1,428 sq.ft.),
RESOLUTION NO. 2001-11
PAGE 2 OF 8
• •
swimming pool (800 sq.ft.), pool house (800 sq.ft.), stable (816 sq.ft.) and service yard
(96 sq.ft.) will have 9,780 square feet which constitutes 5.1% of the lot which is within
the maximum 20% structural lot coverage requirement. A 4,720 square foot basement is
also proposed. The total lot coverage including paved areas and driveway will be 21,400
square feet, which equals 11.2% of the lot which is within the 35% maximum overall lot
coverage requirement. The proposed project is screened from the road so as to reduce
the visual impact of the development. The disturbed area of the lot will be 34%, which
is within the 40% maximum permitted.
B. The development plan substantially preserves the natural and
undeveloped state of the lot by minimizing building coverage because the new
structures will not cause the lot to look overdeveloped. Significant portions of the lot
will be left undeveloped so as to maintain scenic vistas across the property. The
structures proposed will not be visible from Pine Tree Lane. The nature, condition, and
development of adjacent uses, buildings, and structures and the topography of the lot
have been considered, and the construction of the new house, pool house, pool, and a
stable will not adversely affect or be materially detrimental to the adjacent uses,
buildings, or structures because the proposed structures will be constructed on a
portion of the lot which is the least intrusive to surrounding properties, will be screened
and landscaped with trees and shrubs which at maturity will not exceed 25 feet in
height, is a sufficient distance from nearby residences so that proposed structures will
not impact the view or privacy of surrounding neighbors, will improve slope stability
through the use of approved drainage, will permit the owners to enjoy their property
without deleterious infringement on the rights of surrounding property owners.
C. The proposed development, as conditioned, is harmonious in scale and
mass with the site, the natural terrain and surrounding residences. As indicated in
Paragraph A, the lot coverage maximum set forth in the Zoning Code will not be
exceeded and the proposed project is consistent with the scale of the neighborhood.
D. The development plan incorporates existing large trees and native
vegetation to the maximum extent feasible. Specifically, the developmentplan
preserves dense brush and shrubs and supplements it with landscaping that is
compatible with and enhances the rural character of the community.
E. The development plan follows natural contours of the site to minimize
grading and the natural drainage courses will continue to the northwest side (rear and
side) of this lot. Grading for this project will involve 6,200 cubic yards of cut and 6,200
cubic yards of fill and will be balanced on site.
F. The development plan preserves surrounding native vegetation and
mature trees and supplements these elements with drought -tolerant landscaping which
is compatible with and enhances the rural character of the community, and landscaping
provides a buffer or transition area between private and public areas.
G. The proposed development is sensitive and not detrimental to the
convenience and safety of circulation for pedestrians and vehicles because the proposed
project will utilize an existing driveway at the southern portion of the property off Pine
Tree Lane for access.
RESOLUTION NO. 2001-11
PAGE 3 OF 8
• •
H. The project conforms to the requirements of the California Environmental
Quality Act and is exempt.
Section 7. Based upon the foregoing findings, the Planning Commission hereby
approves the Site Plan Review application for Zoning Case No. 629 for proposed
structures as shown on the Development Plan dated May 2, 2001, and marked Exhibit
A, subject to the conditions contained in Section 8 of this Resolution.
Section 8. The Conditional Use Permit for the 800 square foot pool house
approved in Section 5 and the Site Plan Review approved in Section 7 of this Resolution
are subject to the following conditions:
A. The Conditional Use Permit and Site Plan Review approvals shall expire
within one year from the effective date of approval if construction pursuant to these
approvals has not commenced within that time period, as required by Sections
17.42.070(A) and 17.46.080(A) of the Rolling Hills Municipal Code, or the approvals
granted are otherwise extended the Conditional Use Permit and Site Plan pursuant to
the requirements of those sections.
B. It is declared and made a condition of the Conditional Use Permit and Site
Plan Review approvals, that if any conditions thereof are violated, this approval shall be
suspended and the privileges granted thereunder shall lapse; provided that the
applicants have been given written notice to cease such violation, the opportunity for a
hearing has been provided, and if requested, has been held, and thereafter the applicant
fails to correct the violation within a period of thirty (30) days from the date of the
City's determination.
C. All requirements of the Buildings and Construction Ordinance, the
Zoning Ordinance, and of the zone in which the subject property is located must be
complied with unless otherwise set forth in the Permit, or shown otherwise on an
approved plan. All requirements for the basements shall be met subject to Section
17.20.020 of the Zoning Code.
D. The lot shall be developed and maintained in substantial conformance
with the site plan on file marked Exhibit A and dated May 2, 2001, except as otherwise
provided in these conditions.
E. The working drawings submitted to the County Department of Building
and Safety for plan check review must conform to the development plan approved with
this application.
F. Grading shall not exceed 6,200 cubic yards of cut and 6,200 cubic yards of
fill and shall be balanced on site.
G. Structural lot coverage shall not exceed 9,780 square feet or 5.1%.
H. Total lot coverage of structures and paved areas shall not exceed 21,400
square feet or 11.2% in conformance with lot coverage limitations.
RESOLUTION NO. 2001-11
PAGE 4 OF 8
• •
I. The disturbed area of the lot shall not exceed 64,831 square feet or 34.0% of
the net lot area in conformance with lot coverage limitations.
J. Residential building pad coverage on the 26,800 square foot residential
building pad shall not exceed 7,364 square feet or 27.5%; coverage on the 10,640 square
foot pool house, pool and stable pad shall not exceed 2,416 square feet or 22.7%, and
total building pad coverage shall not exceed 26.1%.
K. The size of the pool house shall not exceed 800 square feet. The location of
the pool house shall be as depicted on the Development Plan dated May 2, 2001 and
marked Exhibit A.
L. No sleeping quarters shall be provided within the pool house in
accordance with Section 17.16.210(A)(2) of the Rolling Hills Municipal Code.
M. No kitchen or other cooking facilities shall be provided within the pool
house in accordance with Section 17.16.210(A)(2) of the Rolling Hills Municipal Code.
N. Landscaping shall include water efficient irrigation, to the maximum
extent feasible, that incorporates a low gallonage irrigation system, utilizes automatic
controllers, incorporates an irrigation design using "hydrozones," considers slope
factors and climate conditions in design, and utilizes means to reduce water waste
resulting from runoff and overspray in accordance with Section 17.27.020 (Water
efficient landscaping requirements) of the Rolling Hills Municipal Code.
O. Landscaping for the entire project shall be designed using mature trees,
which at full maturity shall not exceed 25 feet in height, and shrubs so as not to obstruct
views of neighboring properties but, to obscure the pool house and pool area.
P. At maturity, the new landscape plantings around the proposed pool
house, stable and pool shall not exceed the ridge height of the structures.
A bond in the amount of the cost estimate of the implementation of the landscaping plan plus
15% shall be required to be posted prior to issuance of a grading and building permit and shall
be retained with the City for not less than two years after landscape installation. After the two-
year period, upon the request of the applicant, the retained bond will be released by the City
Manager after the City Manager or his designee determines that the landscaping was installed
pursuant to the landscaping plan as approved, and that such landscaping is properly
established and in good condition.
Q. During construction, any soil disturbance shall preserve the existing
topography, flora, and natural features to the greatest extent possible.
U. During construction, conformance with the air quality management district
requirements,stormwater pollution prevention practices, county and local ordinances
and engineering practices so that people or property are not exposed to undue vehicle
trips, noise, dust, and objectionable odors shall be required.
RESOLUTION NO. 2001-11
PAGE 5 OF 8
ea")
•
V. During construction, the Erosion Control Plan containing the elements set
forth in Section 7010 of the 1996 County of Los Angeles Uniform Building Code shall be
followed to minimize erosion and to protect slopes and channels to control stormwater
pollution as required by the County of Los Angeles.
W. During and after construction, all parking shall take place on the project site
and, if necessary, any overflow parking shall take place within nearby roadway
easements.
X. During construction, the property owners shall be required to schedule and
regulate construction and related traffic noise throughout the day between the hours of
7 AM and 6 PM, Monday through Saturday only, when construction and mechanical
equipment noise is permitted, so as not to interfere with the quiet residential
environment of the City of Rolling Hills.
Y. The property owners shall be required to conform with the Regional
Water Quality Control Board and County Health Department requirements for the
installation and maintenance of septic tanks.
Z. The property owners shall be required to conform with the Regional
Water Quality Control Board and County Health Department requirements for the
installation and maintenance of stormwater drainage facilities.
AA. The property owners shall be required to conform with the Regional
Water Quality Control Board and County Public Works Department Best Management
Practices (BMP's) related to solid waste.
AB. A drainage plan system shall be approved by the Planning Department
and County District Engineer, to include any water from any site irrigation systems and
that all drainage from the site shall be conveyed in an approved manner to the rear or
northwest of the lot.
AC. A detailed drainage plan that conforms to the development plan as
approved by the Planning Commission shall be submitted to the Rolling Hills Planning
Department staff for their review and approval.
AD. The working drawings submitted to the County Department of Building
and Safety for plan check review shall conform to the development plan described in
Condition D.
AE. Prior to the submittal of an applicable final building plan to the County of
Los Angeles for plan check, a detailed drainage plan with related geology, soils and
hydrology reports that conform to the development plan as approved by the Planning
Commission shall be submitted to the Rolling Hills Planning Department staff for their
review and approval.
AF. The project must be reviewed and approved by the Rolling Hills
Community Association .Architectural Review Committee prior to the issuance of any
drainage or building permit.
RESOLUTION NO. 2001-11
PAGE 6 OF 8
•
AG. The existing basketball court shall be demolished during the grading
process but prior to issuing any building permits.
AH. The driveway to the property shall be widened to 15 feet.
AI. Until the applicants execute an Affidavit of Acceptance of all conditions of
these Conditional Use Permit and Site Plan Review approvals, as required by Section
17.42.070 or the approvals shall not be effective.
AJ. All conditions of the Conditional Use Permit and Site Plan approvals that
apply shall be complied with prior to the issuance of a building permit from the County
of Los Angeles.
PASSED, APPROVED AND ADOPTED THIS 19TH DAY OF JUNE 2001.
ALLAN ROBERTS, CHAIRMAN
ATTEST: {J•
' l
MARILYN RN, DEPUTY CITY CLERK
RESOLUTION NO. 2001-11
PAGE 7 OF 8
STATE OF CALIFORNIA
COUNTY OF LOS ANGELES ) §§
CITY OF ROLLING HILLS
I certify that the foregoing Resolution No. 2001-11 entitled:
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF
ROLLING HILLS GRANTING SITE PLAN REVIEW APPROVAL TO
PERMIT GRADING AND CONSTRUCTION OF A NEW SINGLE
FAMILY RESIDENCE WITH A POOL, A POOL HOUSE AND A STABLE,
AND GRANTING A CONDITIONAL. USE PERMIT APPROVAL TO
CONSTRUCT A POOL HOUSE AT A VACANT SITE AT 4 PINE TREE
LANE, IN ZONING CASE NO. 629.
was approved and adopted at a regular meeting of the Planning Commission on June
19, 2001 by the following roll call vote:
AYES:
Commissioners Hankins, Margeta, Sommer, Witte and
Chairman Roberts.
NOES: None.
ABSENT: None.
ABSTAIN:. None.
and in compliance with the laws of California was posted at the following:
Administrative Offices.
. ��[ ILA
DEPUTY Cl'!' CLERK
RESOLUTION NO. 2001-11
PAGE 8 OF 8
yY
DATE:
TO:
FROM:
• 6A
City �� /0/fifl4 Jilted INCORPORATED JANUARY 24, 1957
NO. 2 PORTUGUESE BEND ROAD
ROLLING HILLS, CALIF. 90274
(310) 377-1521
FAX: (310) 377-7288
E-mail: cityofrh@aol.com
JUNE 19, 2001
HONORABLE MEMBERS OF THE PLANNING COMMISSION
YOLANTA SCHWARTZ, PRINCIPAL PLANNER
APPLICATION NO. ZONING CASE NO. 629
SITE LOCATION: 4 PINE TREE LANE (LOT 96-1-RH)
ZONING AND SIZE: RA-S-2, 4.9 ACRES
APPLICANT: MR. J. P. CENTOFANTE
REPRESENTATIVE: DOUGLAS McHATTIE, BOLTON ENGINEERING
PUBLISHED: APRIL 7, 2001
REQUEST
Request for a Site Plan Review to permit construction of a new single family residence
that requires grading, a pool, pool house and a stable; and a Conditional Use Permit to
construct a pool house.
BACKGROUND
The Planning Commission at their May 15, 2001 meeting approved a site
plan review and conditional use permit applications in Zoning Case No. 629 and
directed staff to prepare Resolution of approval. The vote was 5-0.
RECOMMENDATION
It is recommended that the Planning Commission adopt Resolution No. 2001-11,
which is attached, approving Zoning Case No. 629.
Pririted on Recycled Paper.
RESOLUTION NO. 2001-11
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF
ROLLING HILLS GRANTING SITE PLAN REVIEW APPROVAL TO
PERMIT GRADING AND CONSTRUCTION OF A NEW SINGLE FAMILY
RESIDENCE WITH A POOL, A POOL HOUSE AND A STABLE, AND
GRANTING A CONDITIONAL USE PERMIT APPROVAL TO CONSTRUCT
A POOL HOUSE AT A VACANT SITE AT 4 PINE TREE LANE, IN ZONING
CASE NO. 629.
THE PLANNING COMMISSION OF THE CITY OF ROLLING HILLS DOES
HEREBY FIND, RESOLVE AND ORDER AS FOLLOWS:
Section 1. Applications were duly filed by Mr. Centofante with respect to real
property located at 4 Pine Tree Lane, (Lot 96-1-RH), Rolling Hills, CA requesting a Site
Plan Review to permit grading and construction of a new residence, a pool house, a
stable, and a pool at a vacant lot, and requesting a Conditional Use Permit to permit the
construction of a pool house.
Section 2. The Planning Commission conducted duly noticed public hearings
to consider the applications on April 17, 2001, May 15, 2001, and at a field trip visit on
May 5, 2001. The applicant was notified of the public hearings in writing by first class
mail. Evidence was heard and presented from all persons interested in affecting said
proposal and from members of the City staff and the Planning Commission having
reviewed, analyzed and studied said proposal. The applicant was in attendance at the
hearings.
Section 3. The Planning Commission finds that the project qualifies as a Class
3 Exemption (The State of CA Guidelines, Section 15303) and is therefore categorically
exempt from environmental review under the California Environmental Quality Act.
Section 4. Section 17.16.210(A)(2) of the Rolling Hills Municipal Code permits
approval for a pool house under certain conditions, provided a Conditional Use Permit
for such use is approved by the Planning Commission. The applicant is requesting
permission to construct an 800 square foot pool house on a secondary building pad
located to the north of the residential building pad. With respect to this request for a
Conditional Use Permit, the Planning Commission finds as follows:
A. The granting of a Conditional Use Permit for the construction of a pool
house would be consistent with the purposes and objectives of the Zoning Ordinance
and General Plan and will be desirable for the public convenience and welfare. The use
is consistent with similar uses in the community, and the area proposed for the pool
house would be located in an area on the property where such use will not dramatically
change the existing configuration of the lot. Section 17.16.040 of the Rolling Hills
Municipal Code permits detached pool houses in the RA-S-2 Zone with a Conditional
Use Permit.
• •
B. The nature, condition, and development of adjacent uses, buildings, and
structures have been considered, and the construction of a pool house will not
adversely affect or be materially detrimental to these adjacent uses, buildings, or
structures because the proposed pool house will be constructed at the central portion of
the lot and is a sufficient distance from nearby residences .to insure that the pool house
will not impact the view or privacy of surrounding neighbors.
C. The project is harmonious in scale and mass with the site, the natural
terrain, and surrounding residences because the pool house will comply with the low
profile residential development pattern of the community and is located on a 4.9 acre
parcel of property that is adequate in size, shape and topography to accommodate such
use.
D. The proposed conditional use complies with all applicable development
standards of the zone district in which it is located because the 800 square foot size of
the pool house is within the 800 square foot maximum permitted and the pool house
does not encroach into any required setback areas.
E. The proposed conditional use is consistent with the portions of the Los
Angeles County Hazardous Waste Management Plan relating to siting and siting
criteria for hazardous waste facilities because the project site is not listed on the current
State of California Hazardous Waste and Substances Sites List.
F. The proposed conditional use observes the spirit and intent of Title 17 of
the Zoning Code by constructing a stable structure and adjacent corral that will be
located on the same building pad.
Section 5. Based upon the foregoing findings, the Planning Commission
hereby approves a Conditional Use Permit for the construction of an 800 square foot
pool house in accordance with the development plan dated May 2, 2001, and marked
Exhibit A in Zoning Case No. 629 subject to the conditions contained in Section 8 of this
resolution.
Section 6. Section 17.46.030 requires a development plan to be submitted for
site plan review and approval before any grading requiring a grading permit or any
building or structure may be constructed or any expansion, addition, alteration or
repair to existing buildings may be made which involve changes to grading or an
increase to the size of the building or structure by at least 1,000 square feet and has the
effect of increasing the size of the building by more than twenty-five percent (25%) in
any thirty-six (36) month period. With respect to the Site Plan Review application
requesting construction of the new house, pool house, pool, and stable at an existing
vacant lot, the Planning Commission makes the following findings of fact:
A. The proposed development is compatible with the General Plan, the
Zoning Ordinance and surrounding uses because the proposed structures comply with
the General Plan requirement of low profile, low density residential development with
sufficient open space between surrounding structures. The project conforms to Zoning
Code setback and lot coverage requirements. The lot has a net square foot area of
190,680 square feet. The proposed residence (5,840 sq.ft.), garage (1,428 sq.ft.),
RESOLUTION NO. 2001-11
PAGE 2 OF 8
• •
swimming pool (800 sq.ft.), pool house (800 sq.ft.), stable (816 sq.ft.) and service yard
(96 sq.ft.) will have 9,780 square feet which constitutes 5.1% of the lot which is within
the maximum 20% structural lot coverage requirement. A 4,720 square foot basement is
also proposed. The total lot coverage including paved areas and driveway will be 21,400
square feet, which equals 11.2% of the lot which is within the 35% maximum overall lot
coverage requirement. The proposed project is screened from the road so as to reduce
the visual impact of the development. The disturbed area of the lot will be 34%, which
is within the 40% maximum permitted.
B. The development plan substantially preserves the natural and
undeveloped state of the lot by minimizing building coverage because the new
structures will not cause the lot to look overdeveloped. Significant portions of the lot
will be left undeveloped so as to maintain scenic vistas across the property. The
structures proposed will not be visible from Pine Tree Lane. The nature, condition, and
development of adjacent uses, buildings, and structures and the topography of the lot
have been considered, and the construction of the new house, pool house, pool, and a
stable will not adversely affect or be materially detrimental to the adjacent uses,
buildings, or structures because the proposed structures will be constructed on a
portion of the lot which is the least intrusive to surrounding properties, will be screened
and landscaped with trees and shrubs which at maturity will not exceed 25 feet in
height, is a sufficient distance from nearby residences so that proposed structures will
not impact the view or privacy of surrounding neighbors, will improve slope stability
through the use of approved drainage, will permit the owners to enjoy their property
without deleterious infringement on the rights of surrounding property owners.
C. The proposed development, as conditioned, is harmonious in scale and
mass with the site, the natural terrain and surrounding residences. As indicated in
Paragraph A, the lot coverage maximum set forth in the Zoning Code will not be
exceeded and the proposed project is consistent with the scale of the neighborhood.
D. The development plan incorporates existing large trees and native
vegetation to the maximum extent feasible. Specifically, the development plan
preserves dense brush and shrubs and supplements it with landscaping that is
compatible with and enhances the rural character of the community.
E. The development plan follows natural contours of the site to minimize
grading and the natural drainage courses will continue to the northwest side (rear and
side) of this lot. Grading for this project will involve 6,200 cubic yards of cut and 6,200
cubic yards of fill and will be balanced on site.
F. The development plan preserves surrounding native vegetation and
mature trees and supplements these elements with drought -tolerant landscaping which
is compatible with and enhances the rural character of the community, and landscaping
provides a buffer or transition area between private and public areas.
G. The proposed development is sensitive and not detrimental to the
convenience and safety of circulation for pedestrians and vehicles because the proposed
project will utilize an existing driveway at the southern portion of the property off Pine
Tree Lane for access.
RESOLUTION NO. 2001-11
PAGE 3 OF 8
• •
H. The project conforms to the requirements of the California Environmental
Quality Act and is exempt.
Section 7. Based upon the foregoing findings, the Planning Commission hereby
approves the Site Plan Review application for Zoning Case No. 629 for proposed
structures as shown on the Development Plan dated May 2, 2001, and marked Exhibit
A, subject to the conditions contained in Section 8 of this Resolution.
Section 8. The Conditional Use Permit for the 800 square foot pool house
approved in Section 5 and the Site Plan Review approved in Section 7 of this Resolution
are subject to the following conditions:
A. The Conditional Use Permit and Site Plan Review approvals shall expire
within one year from the effective date of approval if construction pursuant to these
approvals has notcommenced within that time period, as required by Sections
17.42.070(A) and 17.46.080(A) of the Rolling Hills Municipal Code, or the approvals
granted are otherwise extended the Conditional Use Permit and Site Plan pursuant to
the requirements of those sections.
B. It is declared and made a condition of the Conditional Use Permit and Site
Plan Review approvals, that if any conditions thereof are violated, this approval shall be
suspended and the privileges granted thereunder shall lapse; provided that the
applicants have been given written notice to cease such violation, the opportunity for a
hearing has been provided, and if requested, has been held, and thereafter the applicant
fails to correct the violation within a period of thirty (30) days from the date of the
City's determination.
C. All requirements of the Buildings and Construction Ordinance, the
Zoning Ordinance, and of the zone in which the subject property is located must be
complied with unless otherwise set forth in the Permit, or shown otherwise on an
approved plan. All requirements for the basements shall be met subject to Section
17.20.020 of the Zoning Code.
D. The lot shall be developed and maintained in substantial conformance
with the site plan on file marked Exhibit A and dated May 2, 2001, except as otherwise
provided in these conditions.
E. The working drawings submitted to the County Department of Building
and Safety for plan check review must conform to the development plan approved with
this application.
F. Grading shall not exceed 6,200 cubic yards of cut and 6,200 cubic yards of
fill and shall be balanced on site.
G. Structural lot coverage shall not exceed 9,780 square feet or 5.1%.
H. Total lot coverage of structures and paved areas shall not exceed 21,400
square feet or 11.2% in conformance with lot coverage limitations.
RESOLUTION NO. 2001-11
PAGE4OF8
• •
I. The disturbed area of the lot shall not exceed 64,831 square feet or 34.0% of
the net lot area in conformance with lot coverage limitations.
J. Residential building pad coverage on the 26,800 square foot residential
building pad shall not exceed 7,364 square feet or 27.5%; coverage on the 10,640 square
foot pool house, pool and stable pad shall not exceed 2,416 square feet or 22.7%, and
total building pad coverage shall not exceed 26.1%.
K. The size of the pool house shall not exceed 800 square feet. The location of
the pool house shall be as depicted on the Development Plan dated May 2, 2001 and
marked Exhibit A.
L. No sleeping quarters shall be provided within the pool house in
accordance with Section 17.16.210(A)(2) of the Rolling Hills Municipal Code.
M. No kitchen or other cooking facilities shall be provided within the pool
house in accordance with Section 17.16.210(A)(2) of the Rolling Hills Municipal Code.
N. Landscaping shall include water efficient irrigation, to the maximum
extent feasible, that incorporates a low gallonage irrigation system, utilizes automatic
controllers, incorporates an irrigation design using "hydrozones," considers slope
factors and climate conditions in design, and utilizes means to reduce water waste
resulting from runoff and overspray in accordance with Section 17.27.020 (Water
efficient landscaping requirements) of the Rolling Hills Municipal Code.
O. Landscaping for the entire project shall be designed using mature trees,
which at full maturity shall not exceed 25 feet in height, and shrubs so as not to obstruct
views of neighboring properties but, to obscure the pool house and pool area.
P. At maturity, the new landscape plantings around the proposed pool
house, stable and pool shall not exceed the ridge height of the structures.
A bond in the amount of the cost estimate of the implementation of the landscaping plan plus
15% shall be required to be posted prior to issuance of a grading and building permit and shall
be retained with the City for not less than two years after landscape installation. After the two-
year period, upon the request of the applicant, the retained bond will be released by the City
Manager after the City Manager or his designee determines that the landscaping was installed
pursuant to the landscaping plan as approved, and that such landscaping is properly
established and in good condition.
Q. During construction, any soil disturbance shall preserve the existing
topography, flora, and natural features to the greatest extent possible.
U. During construction, conformance with the air quality management district
requirements, stormwater pollution prevention practices, county and local ordinances
and engineering practices so that people or property are not exposed to undue vehicle
trips, noise, dust, and objectionable odors shall be required.
RESOLUTION NO. 2001-11
PAGE5OF8
• •
V. During construction, the Erosion Control Plan containing the elements set
forth in Section 7010 of the 1996 County of Los Angeles Uniform Building Code shall be
followed to minimize erosion and to protect slopes and channels to control stormwater
pollution as required by the County of Los Angeles.
W. During and after construction, all parking shall take place on the project site
and, if necessary, any overflow parking shall take place within nearby roadway
easements.
X. During construction, the property owners shall be required to schedule and
regulate construction and related traffic noise throughout the day between the hours of
7 AM and 6 PM, Monday through Saturday only, when construction and mechanical
equipment noise is permitted, so as not to interfere with the quiet residential
environment of the City of Rolling Hills.
Y. The property owners shall be required to conform with the Regional
Water Quality Control Board and County Health Department requirements for the
installation and maintenance of septic tanks.
Z. The property owners shall be required to conform with the Regional
Water Quality Control Board and County Health Department requirements for the
installation and maintenance of stormwater drainage facilities.
AA. The property owners shall be required to conform with the Regional
Water Quality Control Board and County Public Works Department Best Management
Practices (BMP's) related to solid waste.
AB. A drainage plan system shall be approved by the Planning Department
and County District Engineer, to include any water from any site irrigation systems and
that all drainage from the site shall be conveyed in an approved manner to the rear or
northwest of the lot.
AC. A detailed drainage plan that conforms to the development plan as
approved by the Planning Commission shall be submitted to the Rolling Hills Planning
Department staff for their review and approval.
AD. The working drawings submitted to the County Department of Building
and Safety for plan check review shall conform to the development plan described in
Condition D.
AE. Prior to the submittal of an applicable final building plan to the County of
Los Angeles for plan check, a detailed drainage plan with related geology, soils and
hydrology reports that conform to the development plan as approved by the Planning
Commission shall be submitted to the Rolling Hills Planning Department staff for their
review and approval.
AF. The project must be reviewed and approved by the Rolling Hills,
Community Association Architectural Review Committee prior to the issuance of any
drainage or building permit.
RESOLUTION NO. 2001-11
PAGE 6 OF 8
• •
AG. The existing basketball court shall be demolished during the grading
process but prior to issuing any building permits.
AH. The driveway to the property shall be widened to 15 feet.
AI. Until the applicants execute an Affidavit of Acceptance of all conditions of
these Conditional Use Permit and Site Plan Review approvals, as required by Section
17.42.070 or the approvals shall not be effective.
AJ. All conditions of the Conditional Use Permit and Site Plan approvals that
apply shall be complied with prior to the issuance of a building permit from the County
of Los Angeles.
PASSED, APPROVED AND ADOPTED THIS 19TH DAY OF JUNE 2001.
ALLAN ROBERTS, CHAIRMAN
ATTEST:
MARILYN KERN, DEPUTY CITY CLERK
RESOLUTION NO. 2001-11
PAGE 7 OF 8
• •
STATE OF CALIFORNIA
COUNTY OF LOS ANGELES ) §§
CITY OF ROLLING HILLS )
I certify that the foregoing Resolution No. 2001-11 entitled:
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF
ROLLING HILLS GRANTING SITE PLAN REVIEW APPROVAL TO
PERMIT GRADING AND CONSTRUCTION OF A NEW SINGLE
FAMILY RESIDENCE WITH A POOL, A POOL HOUSE AND A STABLE,
AND GRANTING A CONDITIONAL USE PERMIT APPROVAL TO
CONSTRUCT A POOL HOUSE AT A VACANT SITE AT 4 PINE TREE
LANE, IN ZONING CASE NO. 629.
was approved and adopted at a regular meeting of the Planning Commission on June
19, 2001 by the following roll call vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
and in compliance with the laws of California was posted at the following:
Administrative Offices.
DEPUTY CITY CLERK
RESOLUTION NO. 2001-11
PAGE 8 OF 8
DATE:
TO:
FROM:
1
City
Of' ROLL`•Ii� LLL_ INCORPORATED JANUARY 24, 1957
NO. 2 PORTUGUESE BEND ROAD
ROLLING HILLS, CALIF. 90274
(310) 377-1521
FAX: (310) 377-7288
E-mail: cityofrh@aol.com
MAY 15, 2001
HONORABLE MEMBERS OF THE PLANNING COMMISSION
YOLANTA SCHWARTZ, PRINCIPAL PLANNER
APPLICATION NO.
SITE LOCATION:
ZONING AND SIZE:
APPLICANT:
REPRESENTATIVE:
PUBLISHED:
REOUEST
ZONING CASE NO. 629
4 PINE TREE LANE (LOT 96-1-RH)
RA-S-2, 4.9 ACRES
MR. J. P. CENTOFANTE
DOUGLAS McHATTIE, BOLTON ENGINEERING
APRIL 7, 2001
Request for a Site Plan Review to permit the construction of a new single family
residence that requires grading, with a pool, pool house and a stable; and a Conditional
Use Permit to construct the pool house.
BACKGROUND
1. The Planning Commission viewed the site and silhouette for the proposed
project on Saturday, May 5, 2001
2. The applicant is requesting Site Plan Review approval for the construction of a
new 5,840 square foot residence with 4,720 square foot basement, 1,428 square foot
garage, 800 square foot pool, 800 square foot pool house, 816 square foot stable and a
service yard at an existing vacant lot. A 1,375 square foot basketball court exists on the
site. The basketball court will be demolished, and therefore is not included in the net lot
and pad coverage calculations. A Conditional Use Permit review is also requested for
the construction of the pool house. The proposed construction requires grading. Site
Plan Review criteria and comparison of nearby residences are attached.
3. The proposed pool house will be located on a secondary building pad, situated
below the residential pad, to the north of the residence. Pursuant to Section 17.16.210 of
the Zoning Ordinance, cabanas and detached recreation rooms require conditional use
permit. No sleeping quarters or kitchen or other cooking facilities are permitted in
cabanas or detached recreation rooms. These conditions will be included in the
conditions of approval, if granted.
4. Grading for the project will require 6,200 cubic yards of cut soil and 6,200 cubic
yards of fill soil, which will be balanced on site.
ZC No. 629
Ping. Comm. 5/15/01 1
Printed on Recycled Paper.
• •
5. The property is zoned RAS-2, and the net lot area is 4(077 acres. The property is
developed with dense trees and bushes, which will remain, except where the
development is proposed. Proposed are two new construction pads totaling 37,440
square feet.
6. • The structural net lot coverage proposed is 9,780 square feet or 5.1%, which
includes the residence, garages, pool, pool house, stable, and the service yard, (20%
permitted); and the total lot coverage proposed including the structures and paved
areas is 21,400 square feet or 11.2%, (35% permitted).
7. Building pad coverage on the 26,800 square foot residential building pad is 7,364
square feet or 27.5 %. Building pad coverage on the 10,640 square foot pool, pool house
and stable pad is 2,416 square feet or 22.7%. The two pads total 37,440 square feet and
will have 26.1% coverage.
8. Disturbed area of the lot will be 34.0%, (40% permitted) of the net lot area.
Disturbance includes any remedial grading (temporary disturbance), any graded slopes
and building pad areas, and any nongraded area where impervious surfaces will
remain or are proposed to be added.
9. In February of 2001 the original 2,882 square foot house, garage and a pool were
demolished. The original house was built in 1937. The applicant is proposing to utilize
the existing apron and the existing driveway, therefore a review by the Traffic
Commission is not required. However, the driveway will be widened from the existing
10 feet to 15 feet. Due to the distance from the road to the proposed residence, the Fire
Department will require that the residence be equipped with a sprinkler system.
According to applicant's representative, the driveway was reviewed and approved by
the Fire Department.
10. Access to the proposed stable will be by a 10-foot wide gravel driveway, located
along the westerly side of the house, with a slope not to exceed 16%.
11. The project has been determined to be categorically exempt pursuant to the
California Environmental Quality Act (CEQA).
RECOMMENDATION
It is recommended that the Planning Commission review the staff report, take
public testimony and direct staff to prepare a Resolution.
ZC No. 629
Ping. Comm. 5/15/01 2
Zoning Case No. 629
SITE PLAN REVIEW II
RA-S- 2 ZONE SETBACKS
Front: 50 ft. from front easement line
Side: 35 ft. from property line
Rear: 50 ft. from property line
STRUCTURES
(Site Plan Review required if size of
structure increases by at least 1,000 sq.ft.
and has the effect of increasing the size of
the structure by more than 25% in a 36-
month period).
STRUCTURAL LOT COVERAGE
(20% maximum)
TOTAL LOT COVERAGE
(35% maximum)
RESIDENTIAL BUILDING PAD
COVERAGE
STABLE /POOL BUILDING PAD
COVERAGE
TOTAL BUILDING PAD COVERAGE
(Guideline maximum of 30%)
GRADING
Site Plan Review required if excavation
and/or fill or combination thereof that is
more than 3 feet in depth and covers more
than 2,000 sq.ft.) must be balanced on
site.
DISTURBED AREA
(40% maximum; any graded building pad
area, any remedial grading (temporary
disturbance), any graded slopes and
building pad areas, and any nongraded
area where impervious surfaces exist.)
STABLE (min. 450 SQ.FT.
& 550 SQ.FT. CORRAL)
STABLE ACCESS
ROADWAY ACCESS
VIEWS
PLANTS AND ANIMALS
EXISTING
VACANT LOT
Residence
Garage
Swim Pool/Spa
TOTAL
Existing driveway off Pine Tree
Lane
N/A
N/A
ZONING CASE NO. 629
Ping. Comm. 5/15/01 3
PROPOSED
SINGLE FAMILY RESIDENCE,
POOL, POOL HOUSE & STABLE
Residence 5,840 sq.ft.
Garage 1,428 sq.ft.
Swim Pool 800 sq.ft.
Stable 816 sq.ft.
Pool House 800 sq.ft.
Service yard 96 sq.ft
Basement 4,720 sq.ft.
TOTAL (excluding . 9,780 sq.ft.
basement
5.1%
11.2%
27.5%
22.7%
26.1%
6,200 cubic yards cut
6,200 cubic yards fill
34.0%
816 sq. ft. stable
550 sq. ft. corral
Accessed by a 10-foot wide trail
from the existing driveway
with a maximum slope to the stable
16%.
Existing driveway off Pine Tree Lane
Planning Commission will review.
Planning Commission will review.
•
NEARBY
PROPERTIES
ADDRESS
3 Pine Tree
Lane
5 Pine Tree
Lane
6 Pine Tree
Lane
12 Upper
Blackwater
Canyon
8 Blackwater
Canyon
OWNER
Bailey
RESIDENCE
(SQ.FT.)
4,720
LOT SIZE
(NET)
223,027
Ullrich 4,286 208,217
Goldberg 6,148 57,064
Lodhie 7,614(Proposed
3.23 acres
Ishak 5,055 148,975
AVERAGE 5,564 155,596
(3.57acres)
PROPOSED 5,840 4.38
ZONING CASE NO. 629
Ping. Comm. 5/15/01 4
DATE:
TO:
FROM:
C1iy o/ RO/IL wee
INCORPORATED JANUARY 24, 1957
NO. 2 PORTUGUESE BEND ROAD
ROLLING HILLS, CALIF. 90274
(310) 377-1521
FAX: (310) 377-7288
E-mail: cityofrh@aol.com
MAY 5, 2001
HONORABLE MEMBERS OF THE PLANNING COMMISSION
YOLANTA SCHWARTZ, PRINCIPAL PLANNER
APPLICATION NO. ZONING CASE NO. 629
SITE LOCATION: 4 PINE TREE LANE (LOT 96-1-RH)
ZONING AND SIZE: RA-S-2, 4.9 ACRES
APPLICANT: MR. J. P. CENTOFANTE
REPRESENTATIVE: DOUGLAS McHATTIE, BOLTON ENGINEERING
PUBLISHED: APRIL 7, 2001
REOUEST
Request for a Site Plan Review to permit the construction of a new single family
residence that requires grading, with a pool, pool house and a stable; and a Conditional
Use Permit to construct the pool house.
BACKGROUND
1. The Planning Commission will view the site and silhouette for the proposed
project on Saturday, May 5.
2. The applicant is requesting a Site Plan Review for the construction of a new 5,840
square foot residence with 4,720 square foot basement, 1,428 square foot garage, 800
square foot pool, 800 square foot pool house, 816 square foot stable and a service yard at
an existing vacant lot. A 1,375 square foot basketball court exists on the site. The
basketball court will be demolished, and therefore is not included in the net lot and pad
coverage calculations. A Conditional Use Permit review is also requested for the
construction of the pool house. The proposed construction requires grading. Site Plan
Review criteria table and comparison of nearby residences table are attached.
3. The proposed pool house will be located on a secondary building pad, situated
below the residential pad, to the north of the residence. Pursuant to Section 17.16.210 of
the Zoning Ordinance, cabanas and detached recreation rooms require conditional use
permit. No sleeping quarters or kitchen or other cooking facilities are permitted in
cabanas or detached recreation rooms. These conditions will be included in the
conditions of approval, if granted.
4. Grading for the project will require 6,200 cubic yards of cut soil and 6,200 cubic
yards of fill soil, which will be balanced on site.
ZC No. 629
Ping. Comm. 5/5/01
Printed on Recycled Paper.
• •
5. The property is zoned RAS-2, and the net lot area is 4,377 acres. The property is
developed with dense trees and bushes, which will remain, except where the
development is proposed. Proposed are two new construction pads totaling 37,440
square feet.
6. The structural net lot coverage proposed is 9,780 square feet or 5.1%, which
includes the residence, garages, pool, pool house, stable, and the service yard, (20%
permitted); and the total lot coverage proposed including the structures and paved
areas is 21,400 square feet or 11.2%, (35% permitted).
7. Building pad coverage on the 26,800 square foot residential building pad is 7,364
square feet or 27.5 %. Building pad coverage on the 10,640 square foot pool, pool house
and stable pad is 2,416 square feet or 22.7%. The two pads total 37,440 square feet and
will have 26.1% coverage.
8. Disturbed area of the lot will be 34.0%, (40% permitted) of the net lot area.
Disturbance includes any remedial grading (temporary disturbance), any graded slopes
and building pad areas, and any nongraded area where impervious surfaces will
remain or are proposed to be added.
9. In February of 2001 the original 2,882 square foot house, garage and a pool were
demolished. The original house was built in 1937. The applicant is proposing to utilize
the existing apron and the existing driveway, therefore a review by the Traffic
Commission is not required. However, the driveway will be widened from the existing
10 feet to 15 feet. Due to the distance from the road to the proposed residence, the Fire
Department will require that the residence be equipped with a sprinkler system.
According to applicant's representative, the driveway was reviewed and approved by
the Fire Department.
10. Access to the proposed stable will be by a 10-foot wide gravel driveway, located
along the westerly side of the house, with a slope not to exceed 16%.
11. The project has been determined to be categorically exempt pursuant to the
California Environmental Quality Act (CEQA).
RECOMMENDATION
It is recommended that the Planning Commission view the site and the silhouette
for the proposed project.
ZC No. 629
Ping. Comm. 5/5/01
2
Zoning Case No. 629
SITE PLAN REVIEW
RA-S- 2 ZONE SETBACKS
Front: 50 ft. from front easement line
Side: 35 ft. from property line
Rear: 50 ft. from property line
STRUCTURES
(Site Plan Review required if size of
structure increases by at least 1,000 sq.ft.
and has the effect of increasing the size of
the structure by more than 25% in a 36-
month period).
STRUCTURAL LOT COVERAGE
(20% maximum)
TOTAL LOT COVERAGE
(35% maximum)
RESIDENTIAL BUILDING PAD
COVERAGE
STABLE /POOL BUILDING PAD
COVERAGE
TOTAL BUILDING PAD COVERAGE
(Guideline maximum of 30%)
GRADING
Site Plan Review required if excavation
and/or fill or combination thereof that is
more than 3 feet in depth and covers more
than 2,000 sq.ft.) must be balanced on
site.
DISTURBED AREA
(40% maximum; any graded building pad
area, any remedial grading (temporary
disturbance), any graded slopes and
building pad areas, and any nongraded
area where impervious surfaces exist.)
STABLE (min. 450 SQ.FT.
& 550 SQ.FT. CORRAL)
STABLE ACCESS
ROADWAY ACCESS
VIEWS
PLANTS AND ANIMALS
EXISTING
VACANT LOT
Residence
Garage
Swim Pool/Spa
TOTAL
Existing driveway off Pine Tree
Lane
N/A
N/A
ZONING CASE NO. 629
Ping. Comm. 5/5/01 3
PROPOSED
SINGLE FAMILY RESIDENCE,
POOL, POOL HOUSE & STABLE
Residence
Garage
Swim Pool
Stable
Pool House
Service yard
Basement
TOTAL (excluding
basement
5.1%
11.2%
27.5%
22.7%
26.1%
6,200 cubic yards cut
6,200 cubic yards fill
34.0%
816 sq. ft.
550 sq. ft. future corral
5,840 sq.ft.
1,428 sq.ft.
800 sq.ft.
816 sq.ft.
800 sq.ft.
96 sq.ft
4,720 sq.ft.
9,780 sq.ft.
Accessed by a 10-foot wide trail
from the existing driveway
with a maximum slope to the stable
16%.
Existing driveway off Pine Tree Lane
Planning Commission will review.
Planning Commission will review.
•
•
NEARBY
PROPERTIES
ADDRESS
3 Pine Tree Lane
5 Pine Tree Lane
6 Pine Tree Lane
12 Upper Blackwater
Canyon
8 Blackwater Canyon
OWNER
Bailey
Ullrich
Goldberg
Lodhie
Ishak
AVERAGE
PROPOSED
RESIDENCE LOT SIZE
(SQ.FT.) (NET)
4,720 223,027
4,286 208,217
6,148 57,064
7,614(Proposed) 3.23 acres
5,055 148,975
5,564 155,596 (3.57acres)
5,840 .4.38
ZONING CASE NO. 629
Ping. Comm. 5/5/01 4
DATE:
TO:
FROM:
•
Ci1y 0/ RO//L _WA
APRIL 17, 2001
713
INCORPORATED JANUARY 24, 1957
NO. 2 PORTUGUESE BEND ROAD
ROLLING HILLS, CALIF. 90274
(310) 377-1521
FAX: (310) 377-7288
E-mail: cityofrh@aol.com
HONORABLE MEMBERS OF THE PLANNING COMMISSION
YOLANTA SCHWARTZ, PRINCIPAL PLANNER
APPLICATION NO. ZONING CASE NO. 629
SITE LOCATION: 4 PINE TREE LANE (LOT 96-1-RH)
ZONING AND SIZE: RA-S-2, 4.9 ACRES
APPLICANT: MR. J. P. CENTOFANTE
REPRESENTATIVE: DOUGLAS McHATTIE, BOLTON ENGINEERING
PUBLISHED: APRIL 7, 2001
REQUEST
Request for a Site Plan Review to permit the construction of a new single family
residence that requires grading, a pool house, a pool and a stable; Conditional Use
Permit to permit the construction of a pool house.
BACKGROUND
1. The applicant is requesting a Site Plan Review for the construction of a new 5,840
square foot residence with 4,720 square foot basement, 1,428 square foot garage,
800 square foot pool, 816 square foot stable and a service yard at an existing
vacant lot. The previous house of approximately 2,882 square feet was
demolished. The proposed garages are located at ninety degrees to each other
and face a common parking court. A Conditional Use Permit review is also
requested for the construction of the pool house. The proposed construction
requires grading. Site Plan Review criteria and a comparison table of nearby
residences are attached.
2. The proposed pool house will be located on a secondary building pad, situated
below the residential pad. Pursuant to Section 17.16.210 of the Zoning Ordinance,
cabanas and detached recreation rooms require conditional use permit. No
sleeping quarters or kitchen or other cooking facilities are permitted in cabanas
or detached recreation rooms. These conditions will be included in the conditions
of approval, if granted.
3. Grading for the project will require 6,200 cubic yards of cut soil and 6,200 cubic
yards of fill soil, which will be balanced on site.
4. The property is zoned RAS-2, and the net lot area is 4.377 acres. The property is
developed with dense trees and bushes, which will remain, except where the
ZONING CASE NO. 629
Ping. Comm. 4/17/01 1
Pririted on Recycled Paper.
development is proposed. Proposed are two construction pads totaling 37,440 •
square feet?
5. The structural net lot coverage proposed is 9,780 square feet or 5.1%, which
includes the residence, garages, pool, pool house, stable and the service yard,
(20% permitted); and the total lot coverage proposed including the structures
and paved areas is 21,400 square feet or 11.2%, (35% permitted).
6. Building pad coverage on the 26,800 square foot residential building pad is 7,364
square feet or 27.5 %. Building pad coverage on the 10,640 square foot pool, pool
house and stable pad is 2,416 square feet or 22.7%. The two pads total 37,440
square feet and will have 26.1% coverage.
7. Disturbed area of the lot will be 33.0%, (40% permitted) of the net lot area.
Disturbance includes any remedial grading (temporary disturbance), any graded
slopes and building pad areas, and any nongraded area where impervious
surfaces will remain or are proposed to be added.
8. In February of 2001 the original 2,882 square foot house, garage and a pool were
demolished. The original house was built in 1937. The applicant is proposing to
utilize the existing apron and the existing driveway, therefore a review by the
Traffic Commission is not required. However, the driveway will be widened
from the existing 10 feet to 15 feet. Due to the distance from the road to the
proposed residence, the Fire Department will require that the residence be
equipped with a sprinkler system.
9. Access to the proposed stable will be by a 10-foot wide gravel driveway from the
existing driveway with a slope not to exceed 16%.
10. The project has been determined to be categorically exempt pursuant to the
California Environmental Quality Act (CEQA).
RECOMMENDATION
It is recommended that the Planning Commission review the Site Plan Review
and Conditional Use Permit requests and take public testimony.
ZONING CASE NO. 629
Ping. Comm. 4/17/01 2
Zoning Case No. 629
SITE PLAN REVIEW
RA-S- 2 ZONE SETBACKS
Front: 50 ft. from front easement line
Side: 35 ft. from property line
Rear: 50 ft. from property line
STRUCTURES
(Site Plan Review required if size of
structure increases by at least 1,000 sq.ft.
and has the effect of increasing the size of
the structure by more than 25% in a 36-
month period).
STRUCTURAL LOT COVERAGE
(20% maximum)
TOTAL LOT COVERAGE
(35% maximum)
RESIDENTIAL BUILDING PAD
COVERAGE
STABLE /POOL BUILDING PAD
COVERAGE
TOTAL BUILDING PAD COVERAGE
(Guideline maximum of 30%)
GRADING
Site Plan Review required if excavation
and/or fill or combination thereof that is
more than 3 feet in depth and covers more
than 2,000 sq.ft.) must be balanced on
site.
DISTURBED AREA
(40% maximum; any graded building pad
area, any remedial grading (temporary
disturbance), any graded slopes and
building pad areas, and any nongraded
area where impervious surfaces exist.)
STABLE (min. 450 SQ.FT.
& 550 SQ.FT. CORRAL)
STABLE ACCESS
ROADWAY ACCESS
VIEWS
PLANTS AND ANIMALS
EXISTING
VACANT LOT
Residence
Garage
Swim Pool/Spa
TOTAL
Existing driveway off Pine Tree
Lane
N/A
N/A
ZONING CASE NO. 629
Ping. Comm. 4/17/01 3
PROPOSED
SINGLE FAMILY RESIDENCE,
POOL, POOL HOUSE & STABLE
Residence
Garage
Swim Pool
Stable
Pool House
Service yard
Basement
TOTAL (excluding
basement
5.1%
11.2%
27.5%
22.7%
26.1%
6,200 cubic yards cut
6,200 cubic yards fill
33.0%
816 sq. ft.
550 sq. ft. future corral
5,840 sq.ft.
1,428 sq.ft.
800 sq.ft.
816 sq.ft.
800 sq.ft.
96 sq.ft
4,720 sq.ft.
9,780 sq.ft.
Accessed by a 10-foot wide trail
from the existing driveway
with a maximum slope to the stable
16%.
Existing driveway off Pine Tree Lane
Planning Commission will review.
Planning Commission will review.
NEARBY
PROPERTIES
ADDRESS
3 Pine Tree Lane
5 Pine Tree Lane
6 Pine Tree Lane
12 Upper Blackwater
Canyon
8 Blackwater Canyon
OWNER
Bailey
Ullrich
Goldberg
Lodhie
Ishak
AVERAGE
PROPOSED
RESIDENCE
(SQ.FT.)
4,720
4,286
6,148
7,614(Proposed)
5,055
5,564
5,840
ZONING CASE NO. 629
Ping. Comm. 4/17/01 4
LOT SIZE
(NET)
223,027
208,217
57,064
3.23 acres
148,975
155,596 (3.57acres)
4.38