none, Remodel & addition to existing, CorrespondenceLockwood -Singh & Associates
A CORPORATION
Consulting Foundation Engineers and Geologists
9977 Jefferson Boulevard • Culver City, California 90230
Telephone: (213) 870-7335
R. RRUGE LOCKWOOD, R.E.G
A WTAR SINGft. C E
November 19, 1975
Dr. Donald Thompkins
No. 11 Saddleback Road
Rolling Hills, California
SUBJECT:
Proj. Ref. 466-52
E[vED
AUG 03 U5
90274 City of Rolling Hills
By
GEOTECHNICAL INVESTIGATION
LOT 48, ROLLING HILLS 201/32
NO.'11 SADDLEBACK ROAD
ROLLING HILLS, CALIFORNIA 90274
Dear Dr. Thompkins:
In accordance with your request, we are pleased to
submit a report of a geotechnical investigation for
proposed residential construction at the address
referenced above.
The accompanying report has been substantiated by sur-
face and subsurface exploration and geologic investi-
gation made in accordance with generally accepted
engineering practice, including those field and
laboratory tests considered necessary in the
circumstances.
It is the professional opinion of the undersigned that
this report presents fairly the information requested
by you.
Respectfully submitted,
LOCKWOOD-SINGH,& ASSOCIATES
R. Bruce Lockwood
REG 204
RBL/AS/HAT:ml
4
Awtar Singh
CE 17727
INTRODUCTION
This investigation was undertaken in order to obtain
information on surface and subsurface geologic and
:soil conditions on Tentative Tract 31906.
The tentative tract is a subdivision of Lot 48 of Rol-
ling Hills. Since there is an existing residence and
no additional development is contemplated on Lot 1,
this investigation is concerned primarily with Lot 2.
This study provides recommendations concerned with grad-
ing and foundation design for a future residence on
Lot 2. A 40-scale grading plan of the site prepared
by South Bay Engineering Company was utilized herein
(Plate A) for delineation of geologic data. A geologic
cross-section was prepared and is included on Plate A.
Proj. Ref. 466-52
Thompkins -2- November 19, 1975
FIELD INVESTIGATION -
Field investigation included geologic reconnaissance
of the subject property and adjacent areas together
with the examination and logging of 3 exploratory
test pits excavated with a backhoe tractor to depths
ranging from 5 to 8 feet. Bag samples of site soils
were obtained for subsequent laboratory testing. All
test pits were backfilled following examination, logging,
and geologic mapping. Logs of the test pits are in-
cluded as Plates B-i through B-.3, inclusive.
SITE CONDITIONS
Location $ Topography
The 'subject property is located on a north trending
ridge on the north flank of the central portion of
the Palos Verdes Hills. Elevations above sea level
within the proposed area of construction range from
about 180 to 196 feet. The ridge slopes northwesterly
at ratios of approximately 8 horizontal to 1 vertical
in the a ea of proposed grading.
Ground Water & DrainaE
No conditions of excessive erosion or instability were
observed during the course of this investigation. No
Proj. Ref. 466-52
Thompkins -3- November 19,,1975
evidence of near -surface ground water was encountered
in the test pits and none is anticipated within depths
pertinent to proposed construction owing to the elevated
position of the site with respect to adjacent drainage
courses.
Surface drainage comprises sheet flow runoff of incident
rainfall derived primarily within the parcel boundaries.
GEOLOGIC CONDITIONS
Earth Materials
Fill
No fill was present on the parcel at the time of the
investigation.
Topsoil
The lot is mantled .by'firm,to stiff, moist, dark brown
fat clays. Topsoil thickness ranges from 2.0 feet as
noted in Test Pit No."3 to 4.0 feet in Test Pits No. 1
and 2. Dessication cracks present in the surface soils
indicates them to be expansive. Expansiveness is that
soil property whereby a volume change results from a
change in moisture content.
Bedrocks
The site is underlain by marine sediments of the Alta-
mira member of the Monterey formation of Miocene geologic
Proj. Ref. 466-52
Thompkins -4- November 19, 1975
age. At this location the Altamira consists of poorly
indurated, buff colored diatomaceous clayey and
sandy shales. No difficulty of excavation is antici-
pated.
GEOLOGIC STRUCTURE AND STABILITY
Bedding plane attitudes exhibited in the Altamira strata
are northwesterly dips ranging from 15° to 39°. Minor
undulations contribute to isolated anomalous attitudes
that deviate from the overall pattern. These structural.
variations are common in the relatively soft shales
of the Altamira throughout the Palos Verdes area. No
evidence of recent or past geologic instability was
observed on the subject property, and bedding inclina-
tions are considered favorable for continued stability
since they are inclined at angles considerably steeper
than the natural slope or dip neutrally with respect
to the slope direction. Factors contributary to the
continued gross site stability, include relatively
gently sloping topography and the favorable bedding
plane attitudes. •, 0 • 0
Proj. Ref. 466-52
Thompkins -5- November 19, 1975
LABORATORY INVESTIGATION .
Laboratory testing was programmed following a review
of the field data and consideration of the probable
foundation design to be evaluated. Laboratory testing
included determination of the compaction characteris-
tics of proposed fill soils and swelling indices of
site bedrocks and topsoil horizon.
Compaction characteristics of probable fill soils
derived from site bedrocks and soil horizon are shown
on Table I, "Summary of Laboratory Density Determina-
tions."
The fat clay topsoil (Soil C) horizon ex1bited a swell-
ing index of 110 which places it in the highly expan-
sive category. Similarly, the clayey diatomaceous
shale (Soil A) with an index of 80 may be classified
as moderately expansive and sandy diatomaceous shale
(Soil B) bedrocks have swelling index of 35.may be
classified as slightly expansive. All expansion tests
were subject to a surcharge of 144 psf.
Proj. Ref. 466-52
Thompkins -6- November 19, 1975
TABLE I.
SUMMARY OF LABORATORY DENSITY DETERMINATIONS
•
Optimum
Soil Maximum Dry* Moisture Content
Type Description Density (Pcf) (% dry wt)
A comminuted,
buff diatomaceous
shale bedrock
84.0 27.0
B comminuted, buff
sandy diatomaceous
bedrock 109 .0 16.5
C Black fat clay
(topsoil horizon)
100.0 21.5
*Compaction standard ASTM D-1557-70 (5 layers)
Proj. Ref. 466-52
Thompkins
-7- November 19, 1975
CONCLUSIONS AND RECOMMENDATIONS
Based on field and laboratory investigation it is the
professional opinion of the undersigned that the pro-
posed subdividion is feasible from the standpoint of
geotechnical conditions. Since no specific construction
plans have been prepared at this time, the following
recommendations are to be considered general and subject
to review prior to commencement of actual development.
Fill
Compacted fill slopes with a maximum vertical height
of 10 feet are considered satisfactory if constructed
at slope ratios not exceeding 2 horizontal to 1 vertical
(2:1). If topsoil material is used in the fill the
slopes may be subject to downhill creep, however, no
structural distress is anticipated if the footings are
placed in bedrock (See section on foundation support).
Cut Slopes
Cut slopes no steeper than 2 horizontal to 1 vertical
(2L1) to a maximum height of 8 feet are considered
satisfactory. The geologic conditions shall be reviewed
by the engineering geologic during construction to
verify the absence of potentially unstable conditions.
Surface Stability of Fill Slopes
Since the probable fill materials are cohesive rather
than granular in nature, excessive erosion of fill
slopes is not anticipated.
Proj. Ref. 466-52
Thompkins -8- November 19, 1975
Drainage
An adequate surface drainage system shall be provided
to direct runoff to adjacent natural drainage courses
in a manner to minimize surface erosion.
Foundation Support
All spread footings shall be placed a minimum of 12 inches
into site bedrocks. No footings are to be placed in
the expansive surface soils.
Since site bedrocks display low to medium expansion
a No. 4 reinforcing steel bar shall be placed at the
top and bottom of the footings.
An allowable bearing value of 1500`psf may be assumed
for foundations placed in site bedrocks. The bearing
value may be increased by 400 psf for each foot of addi-
tional depth of footing below adjacent ground surface
to a maximum of 3000 psf.
Floors
Since the' soils are expansive, conventional wood floors
are recommended., However, if slabs on grade are used
they shall be supported by a minimum thickness of 2
feet of granular non -expansive soil in order to mini-
mize the effects of the underlying expansive soils.
Proj. Ref. 466-52
Thompkins -9- November 19, 1975
Such slabs shall have a minimum thickness of 4 inches
and be reinforced with at least No. 3 bars spaced
at 24 inches on center both ways, or 6x6-6/6 WWF. At
a minimum No. 3 bars;at 24 inches shall be provided
in the footings and be bent 3 feet into the slabs.
A moisture barrier consisting of at least 4 inches of
crushed rock, or plastic waterproof vapor barrier,
such as vinyl with a thickness of at least 6 mils, is
recommended for placement beneath the slab to prevent
upward capillary movement of soil moisture.
The compacted subgrade soils up to 30 inches below low-
est adjacent gradeof floor slabsand paving shall be
premoistened to at least 5% above the optimum moisture
content. The placement and compaction of fill soils
shall be under the observation of the foundation
engineer.
Sewage Disposal
Since sewers are unavailable, a private sewage dis-
posal system will be required. A seepage pit for the
site shall be designed to minimize the likelihood of
saturation ofproposed fills'or seepage from the natural
slope.
Proj. Ref. 466-52
Thompkins -10- November 19, 1975
It is considered advisable, but not mandatory, to per-
form percolation tests at the time the seepage pits
are excavated in order to verify adequate permeability
of subsurface bedrock commensurate with code require-
ments. Verifying an adequate percolation rate at the
time the pits are drilled could obivate costly main-
tenance or the necessity of drilling additional pits
at a later date.
Grading Specifications
1. Prior to placement of compacted fill, the site
shall be cleared of all vegetation, loose topsoil, de-
bris, and any other deleterious materials.
2. Natural slopes steeper than 5 horizontal to 1
vertical shall be benched prior to placement of
fill. The toe of fill slopes shall be provided with
a key with a.minimum depth of 3 feet into the firm
bedrocks.
3. Exposed surfaces receiving fill soils shall be
scarified, aerated or moistened to near optimum
moisture content, and compacted to at least 90% of
the maximum density as determined by ASTM D-1557-70.
Proj. Ref. 466-52
Thompkins -11- November 19, 1975
4. All fill soils shall be placed at or within 3%
of optimum moisture content in lifts not exceeding six
(6) inches in thickness and compacted until field
density tests indicate that a compaction of not less
than 900 of the maximum density has been obtained as
determined by ASTM D-1557. If the excavated natural
soils to be used in the fills are above optimum moisture
content, they shall be dried by windrowing or other
means. Additional water shall be added in case such
fill soils are below optimum moisture content.
5. Field density tests shall be made in accordance with
ASTM D-1556. Field density tests shall be made every
2 feet and not less than one test per 500 cubic yards
of fill placed.
6. Rocks larger than 6" in greatest dimension shall
be excluded from the fill except with the express
approval and in accordancewith the recommendations
of the foundation engineer.
7.• All slopes shall be compacted in a single continu-
ous operation, or all loose soils remaining on the
slopes shall be trimmed back until a surface with a
compaction no less than 90% is. exposed.
8. Planting and irrigation of cut and fill slopes and
installation of erosion control and drainage shall
comply with the requirement of the County Building Law.
Proj. Ref. 466-52
Thompkins -12- November:.19, 1975
Inspection
As'a necessary requisite to the use of this report,
the following shall be observed by the foundation
engineer. or the engineering geologist.
1. Inspection of clearance of vegetation, loose topsoil,
debris, and any other deleterious materials prior to
placement of compacted fill.
2. Inspection. and testing of all compaction infill
which includes key sections, exposed slopes, and back -
fills behind retaining walls.
3. Inspection of all surfaceand subsurface drainage
systems and drainage trenches for the compacted fill.
4. Inspection of drainage blankets behind any retain-
ing walls.
5. Geologic inspection of all cut slopes in bedrock
and natural soil and key sections for compacted fills.
6. ' Inspection of all foundation trenches for the
structure of retaining walls.
7. Inspection of subgrade soils, premoistening of sub -
grade soil, and placement of sand cushions shall be
required prior, to the construction of. slabs.
Proj. Ref. 466-52
Thompkins -13- November 19, 1975
REMARKS
The conclusions and recommendations contained herein
are based on the surface exam nation and the findings
and observations of the test pit locations with an
interpolation of soil conditions between test pit
locations.
Although no significant variations in soil conditions
are anticipated, if conditions are encountered during
construction which appear to be different from those
disclosed by the exploratory work, this office shall
be notified so as to consider the need for modification.
Your atteition is directed to the fact that while cav-
ing was not encountered in the test pits, all shoring
and bracing shall be in accordance with current require-
ments of the Industrial Accident Commission of the
State of California and other public agencies having
jurisdiction.
The report is subject to review by controlling public
agencies having jurisdiction.
_0
5
CLASSIFICATION
DESCRIPTION
0.0-4.0': Topsoil
dry to moist, stiff fat clay,
4.0-6.5': Clayey Diatomaceous Shale
(Tma)
Bedding strikes and dips N50°W, 11°SW,
bedding poorly developed;
tight, discontinuous;
punky to poorly indurated; moderately
fractured; intensely to moderately
weathered; limonite stains on joints : a,id
bedding; Mn02 stains on discontinuitie;;
does not separate preferentially along
beding surfaces, buff -pastel yellow
with rust colored interbeds.
GEOLOGIC SKETCH
2uia-faicel
Topsoil
Tina
I
w o z z
)-OO
M w x- z{ t7zr-,n i
I- JF- U00.6j tiiN OD 00IL.j
o z az w°.. coU Nin o
wo
UON
S 5° W
bedd' g Test Pit Bottom
11.
EQUIPMENT Backhoe LOG OF TEST PIT No. 1 SURFACE ELEVATIONiS2{
PROJECT Thompkins-Saddleback
PROJECT No'466-52 .
LOCKWOOD-SINGH € ASSOC. PLATE B-1 .
-0
5
CLASSIFICATION
DESCRIPTION
0.0-4.0': Topsoil
dry to moist, stiff fat clay
} I- O
r} O
z L u O
DW Y- 2 - G F- l7 1•
-II- UH Q,_, ' In
O S�z �0: 0� InZN�
m
2 U z CO id c �No
0 0�
4.0-8.0': Sandy Diatomaceous Shale (Tna)
Bedding strikes and dips N 10° E,
8-15°NW, bedding poorly developed,
tight, discontinuous; punky to poorly
indurated; moderately fractured; intensely
to moderately weathered; limonite stains on join:s
and bedding, MnO stains on discontinuities.
does not separatt preferentially along
bedding surfaces; buff and pastel
yellow' with rust colored interbeds
bedd n
I i a
GEOLOGIC. SKETCH N 75° W
ile-surface
fTopsoil
Tma
Test Pit Bottom
EQUIPMENT Backhoe LOG OF TEST PIT No.2 SURFACE ELEVATION 196. -
PROJECT T.i pkin.S.:5addleback PROJECT No:466-52
LOCKWOOD-SINGH € ASSOC.
PLATE:B-;2
_0
•
_5
CLASSIFICATION
DESCRIPTION
0.0-2.0': Topsoil
dry to moist, stiff fat.clay
>- H 0
D Z Y0 — Zg z~inO
- .I H cad ES a- o a ,;) in
0 ON Occ 00 wzn?t-
• hZ aQ ow m-mil
or-
O z c ONp
U 0
2.0-5.0': Clayey Diatomaceous Shale ("ma)
Bedding strikes and dips N65-85°E,
25-39°NW; bedding moderately well
developed, tight, discontinuous;
poorly indurated; intensely to moderately
fractured (50o bedding, 50% joints);
moderately -intensely weathered; limoni:e
stains on joints; separates preferentially
along bedding surfaces; mottled buff.,
and reddish brown.
GEOLOGIC SKETCH
surface
N 45° W
•
�-Topsoil J
ma
Test Pit Bottom
EQUIPMENT • Backhoe LOG OF TEST PIT No. 3 SURFACE ELLVATIONTB2.
PROJECT.,..T.b.QTpkin.s.: Saddleback PROJECT No:...,466. 52
LOCKWOOD-SINGH e ASSOC. PLATE B-3
•
dB
dtpiton.stN011,sAs5.4rAtt
: • ;
• ..• ..,„ ' •
. .
4'
Tentative Map 'No. 319 0G
COUNTY 0 F' LOS ANGELES
THE REGIONAL PLANNING COMMISSION
OWNER'S STATEMENT
Date a f 12/15
tft
The following information is required by the various County Departments.
Failure to furnish required information will delay action.
LEGAL DESCRIPTION (All ownerships comprising the proposed division of land.)
(U e e tra §hget if ne ess ry.)
Bock o 1; Po,tps 2.9 icy 3 5 c, Nkgyp
AREA: What is the acreage of this division of land? 32.5
Number of Lots 2
ZONING: Present: 241. -1 Proposed:_, -I
DOMESTIC WATER: Source (Water Co.) Ca.Ui�':. Wes.Jtee Seryyse.. Co.
SEWAGE: Method of Sewage Disposal Qriva*...
GRADING: Is any grading of lots contemplated? Yes No i'e
If yes, show the preliminary grading design on tentative map.
STREET IMPROVEMENTS:• Are standard street improvements contemplated?.
Yes No ye, Are private streets. planned? Yes No }�
USE: Indicate lot numbers under proposed use.
Single Family li a
Multiple Res.
Other
Record Owner(s)
(Attach separate sheet if necessary)
• Name D.2. T betntee- G. Tpw.cle.: s
Address Al' 11 Seal Raout
City Rolli% \kwt
zip code
cb=14
CONSENT (to be
I consent to
Signe' f .. j/
At leas one record owner)
CERTIFICATION: I hereby certify that the above
best of my knowledge.
Signed
Commercial
Industrial
Agricultural
Subdivider
Name G ^"61-L;$
408g:;0614:
Address ;U a, ..(,L_
Phone 377.o1(. , City
ip code
Subdivider's Agent
(Engineer, Licensed Surveyor, other)
Name '54 SZ!_ey 'rC.tiReeriv Corr.
Address 30¢ -1140,n 9 o,,ct
City 4o,Venkos Ez�d�� Phone 172 -1655
, gierk zip code
•
gned if owner of record is not subdivider)
submissi 7of entative map accompanying this .statement.
Phone 377-0/ ?.
c'..
(Subdivider or Subdivider's
Date ,'/'T :'%►���
information is correct to the
Date _11'l'241c
#8