Loading...
none, Remodel & addition to existing, Correspondencet • (310) 544-6222 S oLLinq AIL LL�. �Oir .mtinitLJ C7 iocialioIz ✓✓ a f cRanafzo q/Enctts No. 1 PORTUGUESE BEND RD. • ROLLING HILLS, CALIF. 90274 ROLLING HILLS August 23, 2019 James and Colleen McKinnell 2451 Silverstrand Avenue Hermosa Beach, California 90254 Re: 16 Crest Road East, Rolling Hills, California 90274 Dear Mr. and Mrs. McKinnell, • CALIFORNIA R (310) 544-6766 FAX AUG 292019 ByCity of Rolling Hills Below are the minutes from the August 20, 2019 meeting of the RHCA Architectural Committee relating to your submittal: JAMES & COLLEEN McKINNELL Xero Solar 193-2 — MS 16.Crest Road East Solar Panels on Residence Permit 6724 The Committee made a field trip to the property to view the proposed location for solar panels on the remodeled residence. The Committee reconvened at the Association office at 4:40 P.M. Joe Spierer recused himself from the discussion and the decision of the Committee. The Committee reviewed plans for a solar array on the roof of the residence. The Committee noted the array was contiguous and located on the back of the residence. The solar array was approved as submitted. The decision of the Committee was unanimous; Judy Hollingshead, Bill Rogers, Gordon Inman, George Sweeney, Luls de Moraes. Please note.: The reflection of the sun off solar panels may cause glare on adjoining properties. It is the responsibility of the property owner or installer to mitigate this problem in a timely manner if such an issue arises. Enclosed is your copy of the RHCA Building Permit. Permit fees are due upon receipt; a return envelope is included for your convenience. Please contact Kathryn Bishop for inspection once the solar array is installed. *** This approval does not include City of Rotting Hills approval or Building apo:spfety approvpk Please contact thesa agencies prior to construction. * * • Please feel welcome to. contact me with any questions regarding this letter. Sincer fla c y`i'edesco Architectural Administrator cc: Adam Reinart, Xero Solar s • • EROSOLRR PROJECT DESCRIPTION • • THIS ROOF MOUNTED SOLAR SYSTEM WITH ENERGY STORAGE SYSTEM IS TO BE INSTALLED AT THE SINGLE FAMILY DWELLING IN ROLLING HILLS, CA 90274. A MINIMUM OF 75% OF THE ENERGY USED TO CHARGE THIS BATTERY SYSTEM IS TO BE PRODUCED BY THE NEW SOLAR ARRAY ON -SITE. THE ENERGY OUTPUT FROM THIS ENERGY STORAGE BATTERY SHALL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE NEW ON -SITE ELECTRICAL EQUIPMENT VIA A BACK - FEED BREAKER IN THE MAIN SERVICE PANEL. THIS BATTERY IS TO BE CYCLED TO THE GRID ONE TIME PER WEEK AND ALL CONTROLS AND MONITORING METERS ARE MANAGED BY THE MANUFACTURERS CONTROL SYSTEMS. SHEET INDEX T1.0 COVER PAGE A1.0 SITE PLAN A1.1 ROOF PV LAYOUT A1.2 STRING LAYOUT A2.0 ATTACHMENT DETAIL E1.0 ELECTRICAL LINE DIAGRAM E1.1 ELECTRICAL CALCULATION E2.0 SAFETY PLACARDS E3.0 ELECTRICAL ELEVATION VIEW DETAIL D1.0 MODULE DATA SHEET D2.0 RACKING DATA SHEET D3.0 RACKING DATA SHEET D4.0 ATTACHMENT DATA SHEET D5.0 TESLA POWERWALL DATA SHEET D6.0 TESLA POWERWALL DETAILS D7.0 METHOD & MATERIALS D8.0 BACKUP GATEWAY DATA SHEET SITE SPECIFICATIONS: OCCUPANCY CATEGORY: II DESIGN WIND SPEED: 100 MPH EXPOSURE CATEGORY: B GROUND SNOW LOAD: 0 PSF AERIAL MAP SCOPE OF WORK: (36) PV MODULES (SPR-X22-370-D-AC (240) [SI1]) (TOTAL: 631.44 SQ. FT.) SYSTEM SIZE: (13.32) KW DC STC, (11.52) KW AC CEC (36) SUNPOWER P370 MICRO INVERTER (68) ATTACHMENT POINTS @ 48" O.C. MAX. (1) PV COMBINER PANEL 125A, TYP. (1) AC DISCONNECT 60A NON -FUSED, 240V NEMA 3R, UL LISTED, (1) GENERATION PANEL, 200 AMP, 2-P, NEMA 3R, UL LISTED (2) 13.5 KWH TESLA POWER WALL, UL LISTED, NEMA 3R (1) TESLA ENERGY GATEWAY 200 A, UL LISTED, NEMA 3R, INTEGRATED NEURIO GATEWAY AND CONTROLS GOVERNING CODES 2017 LA COUNTY ELECTRICAL CODE (2016 CEC, 2014 NEC) 2017 LA BUILDING CODE 2017 LA MECHANICAL CODE 2013 NATIONAL FIRE ALARM CODE (NFPA 72) 2016 CALIFORNIA ENERGY CODE 2017 LA GREEN CODE (LAGC) UNDERWRITERS LABORATORIES (UL) STANDARDS OSHA 29 CFR 1910.269 RECIENED AUG 292019 City of Rolling HMIs By ilos Verdes Estates Rancho 3alos Verdes itl_lt.r a Railing Hills Estatc.3 Lore 16 Crest Road East Bat:ie,iiia t3SS t lcwa tviuseuci .; Terminal' Island fe Ports 0' Call Cabrii;c Marine ;:ecn Fn=•ns d"in Bell C4;: 'r nrl,_arit:m. - PROJECT LOCATION VICINITY MAP 12 CONSTRUCTION NOTES: 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO INITIATING CONSTRUCTION. 2. CONTRACTOR SHALL REVIEW ALL MANUFACTURER INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. 3. ALL EQUIPMENT SHALL BE LISTED BY U.L. (OR EQUAL) AND LISTED FOR ITS SPECIFIC APPLICATION. 4. ALL EQUIPMENT SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED. 5. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 6. ACCESS TO ELECTRICAL COMPONENTS OVER 150 VOLTS TO GROUND SHALL BE RESTRICTED TO QUALIFIED PERSONNEL. 7. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 VOLTS AND 90°C WET ENVIRONMENT, UNLESS OTHERWISE NOTED. 8. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES. 9. PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE COPPER E.G.C. PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. 10. PV MODULE RACKING RAIL SHALL BE BONDED PER MANUFACTURERS UL 2703 LISTING SPECIFICATIONS. 11. ALL JUNCTION BOXES, COMBINER BOXES, AND DISCONNECTS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION. 12. ROOF ACCESS POINTS SHALL BE AT A STRONG POINT ON THE BUILDING AND NOT REQUIRE THE PLACEMENT OF LADDERS OVER EXTERIOR WALL OPENINGS. 13. WORKING SPACE AROUND ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26 14. THE POWERWALL WILL NEVER REQUIRE EXAMINATION, SERVICING, OR MAINTENANCE WHILE ENERGIZED. THEREFORE WORKING CLEARANCES OUTLINES IN NEC 110.26 ARE NOT APPLICABLE. 15. THE TESLA BCKUP GATEWAY HAS BEEN LISTED FOR USE AS SERVICE EQUIPMENT, IF USED AS A SERVICE DISCONNECT THE MAIN BONDING JUMPER MUST BE INSTALLED. 358 Coral Circle El Segundo, CA 90245 Ben Lochtenberg CSLB License# 992157 Phone No: (310) 376-8740 REVISIONS DESCRIPTION DATE REV FOR RENEW 07.242019 A DRAWN BY: A. REINART PROJECT NAME & ADDRESS MCKINNELL SHEET NAME COVER PAGE SHEET SIZE ANSI B 11"X17" SHEET NUMBER T1.0 • • 21S-0" • pROPERTY LINE • • \ 60, \ • `' PROVED %4-_3 1 PLOT PLAN WITH ROOF PLAN A1.0 SCALE: 1/32" = 1'-0" Date: (E) MAIN SERVICE PANEL — ROOF #1 — (36) SUNPOWER SPR-X22-370-D-AC (240) [SI1] MICRO INVERTER MODULES CITY OF ROLLING Approved by: • S PLANNING E ( TIUN, E - ai 1. 41‘64I7%%0/2) r DETACHED STRUCTURE 103'-8" PRE-�E_l/ (E) FENCE (N) TESLA POWERWALL (TYP.) — (N) LOAD CENTER (E) SUB PANEL (E) EV CHARGER ma=aa.... Q� (E) DRIVEWAY CREST E 2 GARAGE SECTION DETAIL A1.0/2 SCALE: NTS XE:ROSOLRR 358 Coral Circle El Segundo, CA 90245 Ben Lochtenberg CSLB License# 992157 Phone No: (310) 376-8740 REVISIONS DESCRIPTION DATE REV FOR RENEW 07.24.2019 A DRAWN BY: A. REINART PROJECT NAME & ADDRESS MCKINNELL SHEET NAME SITE PLAN SHEET SIZE ANSI B 11" X 17" SHEET NUMBER A1.0 • • • sr) T T-rr-r T. Tn. :7 DULE TYPE, DIMENSION WEIGHT UMBER OF MODULES = 36 MODULES MODULE TYPE = SUNPOWER SPR-X22-370-D-AC (240) [SI1] MICROINVERTER MODULES MODULE WEIGHT = 45.5 LBS / 20.6 KG. MODULE DIMENSIONS = 61.3"x 41.2" = 17.54 SF UNIT WEIGHT OF ARRAY = 2.68 PSF (36) SUNPOWER P370 - MICRO INVERTER (N) SUNPOWER INVISIMOUNT - RACKING SYSTEM (68) UNIRAC 4" 2-PIECE - STANDOFF @ 48" O.0 ROOF #1 - (36) SUNPOWER SPR-X22-370-D-AC (240) [SI1] MICRO INVERTER MODULES 1 ROOF PV LAYOUT A1.1 SCALE: 1/16" = 1' 1' •///7 z • / f� % 'I/ ' / /. 18' FIRE SETBACK •,.YY/ /, (N) PV COMBINER PANEL (N) AC DISCONNECT - (E) UTILITY METER - (E) MAIN SERVICE PANEL -t 3/4" EMT CONDUIT RUN - MIN. 1/2" ABOVE ROOF (N) JUNCTION BOX (E) SUB PANEL (N) TESLA ENERGY GATEWAY (N) GENRATION PANEL 4CD Dig` "Q) /.< "Tp %<"1/ s 1' -1 z (N) TESLA POWERWALL (INSIDE GARAGE )(TYP.) (N) LOAD CENTER (INSIDE GARAGE) (E) SUB PANEL (INSIDE GARAGE) (06 CA- /O LEGEND - UTILITY METER - JUNCTION BOX - MAIN SERVICE PANEL -AC DISCONNECT - PV LOAD CENTER - SUB PANEL UM JB MSP ACD PVC SUB ROOF DESCRIPTION ROOF TYPE COMP SHINGLE ROOF ROOF ROOF AZIMUTH RAFTERS RAFTERS TILT SIZE SPACING #1 18° 21° 2"x8" 16" O.0 ARRAY AREA & ROOF AREA CALC'S ROOF ARRAY ROOF AREA ROOF AREA AREA COVERED (Sq. Ft.) (Sq. Ft.) BY ARRAY (%) 36 631.44 1601.05 39 #1 # OF MODULES (E) CHIMNEY 1.81" 41.2"h CO lI SUNPOWER SPR-X22-370-D-AC (240) [SI1] MICROINVERTER MODULES - VENT, SKYLIGHT (ROOF OBSTRUCTION) - ROOF ATTACHMENT - RAFTERS - CONDUIT - RAIL - CHIMNEY XEROSOLRR 358 Coral Circle El Segundo, CA 90245 Ben Lochtenberg CSLB License# 992157 Phone No: (310) 376-8740 REVISIONS DESCRIPTION DATE REV FOR RENEW 07.242019 A DRAWN BY: A. REINART PROJECT NAME & ADDRESS MCKINNELL 07 ti W N Q O Q O O < CC U H • J WcK U = z 0 SHEET NAME ROOF PV LAYOUT SHEET SIZE ANSI B 11" X 17" SHEET NUMBER A1.1 EQUIPMENT SOLAR PV MODULE INVERTER AC DISCONNECT PV COMBINER PANEL TESLA POWER WALL GENERATION PANEL TESLA ENERGY GATEWAY ATTACHMENT RAILS RAILS RAIL SPLICE MID CLAMPS END CLAMPS 1 A1.2 QTY 36 36 BILL OF MATERIALS DESCRIPTION SUNPOWER SPR-X22-370-D-AC (240) [SI1] MODULES SUNPOWER P370 MICRO -INVERTER AC DISCONNECT100A NON -FUSED, 240V NEMA 3R, UL LISTED, 1 PV COMBINER PANEL 125A, TYP. 2 13.5 KWH TESLA POWER WALL, UL LISTED, NEMA 3R GENERATION PANEL, 200 AMP, 2-P, NEMA 3R, UL LISTED TESLA ENERGY GATEWAY 200 A, UL LISTED, NEMA 3R 68 UNIRAC 4" 2-PIECE STANDOFF 0 INVISIMOUNT RAILS-122" SECTION 20 INVISIMOUNT RAILS-162" SECTION 16 SPLICE KIT 68 MID CLAMPS 8 END CLAMPS STRING LAYOUT SCALE: 1/16" = 1' STRING #2 — — STRING #3 A /41 is �i �2�-;7 — — : %//', _%r" ''///%/, j/i: .-`ir !/���J ;`%%1i=v`hi�i :<71eFIRE SETBACK I POINT OF INTERCONNECTION 37 %tea. -: i%.i�>i,i . =I — STRING #1 1 STRING #1 — — — — STRING #2 STRING #3 XEROSOLRR 358 Coral Circle El Segundo, CA 90245 Ben Lochtenberg CSLB License# 992157 Phone No: (310) 376-8740 REVISIONS DESCRIPTION DATE REV FOR REVIEW 07.24.2019 A DRAWN BY: A. REINART PROJECT NAME & ADDRESS MCKINNELL SHEET NAME STRING LAYOUT SHEET SIZE ANSI B 11" X 17" SHEET NUMBER A1.2 • XEROSOLRR 1 A2.0 SEE (2/A2.0) FOR ENLARGED VIEW ATTACHMENT DETAIL SCALE: NTS CHANNEL NUT SUNPOWER INVISIMOUNT RACKING SYSTEM COMP. SHINGLE ROOF 2"x8" RAFTERS @ 16"OC 2 ATTACHMENT DETAIL (enlarged section view) A2.0 SCALE: NTS PV MODULE GROUNDING END/MID CLAMP PV MODULE UNIRAC INVERTED L-FEET UNIRAC 4" 2-PIECE STANDOFF 5/16"X3.5" SS LAG BOLT WITH MIN 21/2" THREAD EMBEDMENT, SEALED PENETRATION NOTE: WEATHER PROOFING DONE BY ROOFER 358 Coral Circle El Segundo, CA 90245 Ben Lochtenberg CSLB License# 992157 Phone No: (310) 376-8740 REVISIONS DESCRIPTION DATE REV FOR REVIEW 07.24.2019 A DRAWN BY: A. REINART PROJECT NAME & ADDRESS MCKINNELL Cn uw N- CV ❑ O < CA O < � U W J U= (CO J J 0 0:: SHEET NAME ATTACHMENT DETAIL SHEET SIZE ANSI B 11" X 17" SHEET NUMBER A2.0